Descargar Imprimir esta página

Fuji FRC-200-1 Manual Del Operario página 12

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
Operator's Manual
Usable Limit of Main Components
Parts name
Limit for replacement
Rotor blade
The height of Rotor Blade:
Lower than 9.9 mm
The length of Rotor Blade:
Shorter than 69.3 mm
Uneven Wear
The surface of the Rotor Blade gets
rough.
The edge of the Rotor Blade is
cracked.
Cylinder
Closest-contact point:
Thinner than 7.47 mm
Concave spots can be seen in the inner
wall of the Cylinder
Bearing
Play between the inner lace and the
outer lace is rather big.
Noise can be heard in rotation.
Rotation is not smooth.
Troubleshooting
Symptom
Cause
Spindle not
No air supply
turning or
Turning is
Lubrication not
slow
enough
Air line filter is
clogged
Malfunction of air
motor
12
Countermeasure
Open the line valve or
the throttle valve.
Supply turbine oil to
the motor part and
lithium grease to the
gear part
Clean the air filter
Repair is needed
© Fuji Industrial Technique Co., Ltd. - 9502001250
Symptom
Cause
Shaving
Lower air pres-
capacity is
sure
down
Lubrication not
enough
Air line filter is
clogged
Malfunction of air
motor
Cutter is worn
Spindle is
Spindle is worn
not rotating
smoothly
Machine
Lubrication not
Housing
enough
gets higher
in tempera-
ture
Lubrication
Use an air line lubricator with Turbine Oil ISOVG32 or
equivalent, adjusted to two (2) drops per minute. Not
lubricated air will cause unexpected parts wear and reduce
operation efficiency.
Lithium grease is recommended to be used for Ball Bear-
ing, Gears and Gear Casing.
Maintenance instructions
Follow local country environmental regulations for
safe handling and disposal of all components.
Maintenance and repair work must be carried out by
qualified personnel using only original spare parts.
Contact the manufacturer or your nearest authorized
dealer for advice on technical service or if you require
spare parts.
Always ensure that the machine is disconnected from
energy source to avoid accidental operation.
Disassemble and inspect the tool every three 3 months
if the tool is used every day. Replace damaged or worn
parts.
Disposal
The disposal of this equipment must follow the legisla-
tion of the respective country.
All damaged, badly worn or improperly functioning
devices MUST BE TAKEN OUT OF OPERATION.
Repair only by technical maintenance staff.
FRC-200-1
Countermeasure
Increase air pressure
Supply turbine oil to
the motor part and
lithium grease to the
gear part
Clean the air filter
Repair is needed
Replace it with brand
new one
Repair is needed
Supply turbine oil to
the motor part and
lithium grease to the
gear part
Oil supply speed of the
Oiler must be made
faster