Dead Man :
the functioning of a Dead Man consists in having to always
keep the control button pressed to make the control unit open;
once the command is released, the control unit stops the
window.
A further command always maintained closes the window.
Dead Man during Closing Phase :
the functioning of Dead Man only in the closing phase, consists
in always having to keep pressed the control button to make the
control unit perform the closing; once the command is released,
the control unit stops the window, while in the Opening phase
the operation is impulsive (see Step by Step operation).
Other :
Automatic Closing :
The control unit allows you to close the window automatically
without sending additional commands.
The choice of the time is selectable thanks to the dedicated
SEAV "BeTech" application.
PED : Pedestrian crossing :
The control unit allows, using both the dedicated "BeTech"
SEAV application and the radio remote control, to operate the
motor for a programmable time, such as access to a pedestrian
beyond normal operation.
D.S. : Security Device ( Photocell ):
The control unit allows the power supply and connection of
photocells, pneumatic ribs (NC).
The intervention of the photocells in the opening phase is not
considered, in the closing phase causes the inversion of the
motion.
Warning: this input, if not used, must be bridged or
deactivated using the dedicated "BeTech" SEAV application.
FCAP – FCCH : opening & closing limit switch:
The control unit allows the connection of opening and closing
limit switch (NC). The intervention in the respective operating
phases
causes
the
immediate
Warning: these inputs, if not used, must be bridged or
deactivated using the dedicated "BeTech" SEAV application.
Motor Power
:
The electronic control unit, using the dedicated SEAV "BeTech"
application via Smartphone, allows the regulation of the Force
and Speed of the motor, completely managed by the
microprocessor. The adjustment can be made with a range from
0% to 100% of the maximum force.
For each movement, however, an initial cue is provided, feeding
the engine for 2 seconds at maximum power even if the motor
force adjustment is activated.
Attention: A variation of the Motor Force requires the repetition
of the learning procedure, as it will vary the times of maneuver
and slowdown.
Deceleration / Deceleration Power :
The motor deceleration function is used in the gates to avoid
the high-speed stop of the leaves at the end of the opening and
closing phase.
If the slowdown is active, if the slowdown is activated, during
the Motor Time programming it is also possible to program the
slow motion time at the desired points. In addition, the
electronic control unit, using the dedicated SEAV "BeTech"
application via Smartphone, allows to exclude the slowdown
and to adjust the Motor Force during this phase.
Connection with TIMER:
stop
of
the
motion.
The control unit can have a timer set up instead of an open-
close control button.
Example: at 08:00 the timer closes the contact and the control
unit opens the gate. At 18:00 the timer opens the contact and
the control unit closes the gate. During the interval between
08:00 and 18:00, at the end of the opening phase, the control
unit disables the flashing beacon, automatic closing and radio
controls.
Settings :
The control panel is supplied by the manufacturer with the
possibility of selecting some important functions, using the
dedicated SEAV "BeTech" application.
CODE : (Programming of the radio remote control)
The control unit can memorize up to 100 radio controls with
different
codes
like
The transmission code must be programmed as follows: press
the CODE key of the "BeTech" SEAV application via
Smartphone, at the same time send the desired code of the
desired radio control; when the control panel will issue a
confirmation beep, the programming will be completed. If all the
330 codes have been memorized, repeating the programming
operation, the control unit will emit a long Beep signaling that no
further memorization is possible.
DELETE Remote Control:
The cancellation of all the memorized codes is carried out as
follows: press the DELETE key of the "BeTech" SEAV
application via Smartphone, at the same time the control unit
will emit a confirmation beep, preceded by messages visible on
the Smartphone.
CODE PED: (Pedestrian. radio control code)
The programming and erasing procedure is similar to the one
described above but obviously referred to the CODE PED of the
SEAV "BeTech" application.
Programming by Remote RCD :
The electronic control unit, using the dedicated SEAV "BeTech"
application via
Smartphone,
Programming function of a remote radio remote control by
means of a remote control already present in the memory: The
remote radio control programming is carried out as follows:
send in Continuous mode for a time greater than 10 seconds
the code of a previously memorized radio control, at the same
time the control unit enters programming mode as described
above in the CODE paragraph.
Flashing : (Flashing output operation)
The control panel has a 230Vac output for connecting a
flashing light or a courtesy light.
The electronic control unit, using the dedicated SEAV
"BeTech" application, allows the choice of the functioning
of the 230V Flashing output:
- Curtesy Light : Courtesy light active for 3 minutes
following an opening command.
- T. Mot. : Flashing active only during ON motors.
- T. Mot. + Automating Clos. Time : Flashing active
only during ON motors and during Automatic Closing
Time.
7
Fix,
Rolling
Code
or
allows you
to select
rev. 1.0 01/06/2021
Plus.
the