EN
Safety Protection
I. BMS Protection
1. Supported protection:
Over-discharging protection, cell protection, short-circuit protection, overload protection, low-temperature
protection, high-temperature protection, overvoltage protection, and overcurrent protection.
2. Measures to release protection:
① Over-discharging protection, cell protection, short-circuit protection, overload protection, overvoltage
protection, and overcurrent protection — protection can be released by leaving the device idle for more
than 1 minute after removal.
② Low-temperature protection, high-temperature protection — protection can be released by removing
the device and placing the battery within the working temperature range (discharging temperature
between -10℃ and 55℃, charging temperature between 0℃ and 40℃).
II. Port Protection
1. Supported protection:
Overvoltage protection, overcurrent protection, limited charging / discharging during abnormalities.
2. Measures to release protection:
Protection can be released by leaving the device idle for more than 1 minute after removal.
Port power allocation
Intelligent dynamic allocation is adopted to calculate the discharging power consumed by all ports in real
time, and to determine the remaining available discharging power. If the remaining power
of Port, discharging is allowed; otherwise, discharging for the remaining ports is restricted to prevent sudden
termination of discharging in the currently utilized interfaces, which may damage the device. Once the load
is removed from an occupied port, the allocated power will be redistributed. The total power output from
all interfaces shall not exceed 155 W.
≥
Rated Power