INSTRUCTIONS FOR INSTALLATION ON SLOPING ROOF

Contents of kit 076186X0 (used for a single collector)
X4
1 -
Assemble the supporting structures accord-
ing to the number of collectors to be installed,
fitting the profiles together (fig. 2).
For version VMF/VMFA is necessary to take
into account that indicated in section 7.
fig. 2
3 - Fix the supporting structures on the fastenings previously prepared on the roof, depending on the type of covering (fig. 4),
following the instructions contained in the kit.
Note: When high stresses on the structure are foreseen (e.g. heavy snowfall, wind gusts, etc.) it is advisable to increase the
fixing points as given in the diagram of fig. 1.
Important: The weights of the collector and any additional weights will be supported by the brackets which in turn will rest on
the roofing tiles. Therefore correctly check their load bearing capacity before carrying out installation
Installation on curved tiles
Min.
65 mm
4 - Establish the positioning of the upper bracket, following the indications of fig. 5.
32
EN
X2
X2
(60x25x1195)
2 -
Fit the brackets (fig.3)
Installation on flat tiles
10 Nm
cod. 3541D350 - Rev. 03 - 11/2014
ECOTOP VMF/VMFA/VRF/VRFA
X4
(M8x75 hex. socket screws)
10 Nm
fig. 4
fig. 5
X2
(55x20x295)
fig. 3
Installation with studs
20 Nm