7 - Version VMF/VMFA: insert the seal (fig. 8a)
Version VRF/VRFA: insert the union (fig. 8b)
Version VMF/VMFA
Solar panel
40 mm
fig. 8a
In versions VMF/VMFA, with installations of more than 4 collectors, the expansion joint must be inserted at the
places shown in fig. 9c. For installation, follow the instructions contained in the kit 072218X0.
Contents of kit 072218X0
X2
X2
(55x20x395)
Code 072218X0
expansion joint kit
115 mm
80 mm
fig. 9a
34
EN
ECOTOP VMF/VMFA/VRF/VRFA
Installation of brackets for expansion joint
X5
X4
(M8x75 hex. socket
screws)
fig. 9b
With 5 and 6 panels
cod. 3541D350 - Rev. 03 - 11/2014
Version VRF/VRFA
Solar panel
Fixing CLIP
fig. 8b
80 mm
1
2
3
4
fig. 9c
O-rings already fi tted
Code 072220X0
40 mm
55x20x395
With 7 and 8 panels
5
6
7
8

Publicidad