• Only operate the device when the casing is closed.
• Only operate the device mounted on the wall.
Warning: Power surges, which may occur during electrical storms, can cause life-
threatening electric shocks, or damage or destroy the PBX.
• Do not touch the PBX or any devices connected to it during an electrical storm.
Requirements:
• A wide flat-bladed screwdriver
• A non-slip surface
1.
Push the screwdriver into the opening
on the upper edge of the cover and pull
it upward.
The lock is released and the cover is
pulled slightly upward.
2.
Push the cover towards the screwdriver.
3.
Push the cover far enough (approx. 15 cm) that you can lift it out of the casing vertically
without resistance.

Updating or Upgrading the PBX

Warning: Touching voltage-carrying conductors or phone connections can cause
life-threatening electric shocks. The PBX contains hazardous voltages, even outside
of the power supply unit (for instance ringer voltages). Work on active, contact-
hazardous parts is only permitted after creating a voltage-free state. Working close to
active parts is only permitted if these parts are voltage-free or are protected against direct
contact .
• Pull out the PBX's power plug. Also disconnect the device from additional power sources
(e. g. UPS, if installed).
• Wait at least 3 minutes for the discharge of any capacitor in the device after
disconnecting it from the main power supply.
Caution: Electrostatic charges can destroy sensitive components.
•Discharge electrostatic charges from yourself before touching the circuit boards
with your hands or any tools. To do this, touch a preferably earthed metal object, such
as the PBX's earthing terminal or a computer case.
Important: Before you insert a module, first make the necessary port settings on the
module (operating modes and terminators).
Make sure that the module is fastened on the edge centred in relation to the connector.
COMmander 6000/R/RX - Instructions V11 11/2018