Connecting The Pc; Closing The Casing; Turning On The Pbx - Auerswald COMmander 6000 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 70
• Proper earth connection close to the installation site (equipotential bonding rail of the
house installation or protective earth conductor)
• No terminals connected
1.
Connect the connecting cable to the potential
compensation bar of the house installation or the
protective earth conductor.
2.
Insert the connecting cable into the casing and
connect it to the earth terminal on the main circuit
board.

Connecting the PC

Requirements:
• Available network socket on the PC or in the network of the PC
1.
Insert one end of the accompanying network cable into the network socket on the PC or
in the network of the PC.
2.
Insert the other end of the network cable into the RJ-45 socket of the basic unit or of the
last VMF/VoIP module.

Closing the Casing

Notes: The mounting frame is equipped with fastening hooks for
securing the cables.
The connections for the first commissioning (connection to a PC/
network and, if necessary, connection of a few terminals) must
be made before the casing is closed. Alternatively, you can
prepare them by laying a connecting cable that leads out of the
housing.
Requirements:
• Cables carefully reinserted into the cable space after
installation
1.
Place the casing cover approx. 15 cm towards the
top by sliding it onto the casing so that it just covers
the base circuit board. At this height the casing
cover can be placed in position without resistance.
2.
Finally, pull the cover vertically downwards until it
clicks into position.

Turning on the PBX

Warning: Touching voltage-carrying conductors or phone connections can cause
life-threatening electric shocks.
COMmander 6000/R/RX - Instructions V11 11/2018
Commissioning (COMmander 6000)
57

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Commander 6000rxCommander 6000r

Tabla de contenido