4. TECHNICAL FEATURES
EN
Installation height
Detection angle
Power supply
Consumption
Light output (L↓)
Ventilation output
(H1 - H2)
Settings
Protection index (IP)
Class of electrical
insulation
Connection capacity
Usage conditions
Appearance
ATTENTION: The CPTA must be secured on its electrical supply circuit by a type B or C diffe-
rential circuit breaker (EN 60898-1) rating 10A max.
Each time it is turned on, the sensor performs a 45-second warm-up phase,
during which:
• Red LED turns on and then turns off.
• Output L↓ = 230V and then 0V.
• Output H1-H2 = contact closed and then contact open.
16
CPTA-S N
(attached to the ceiling)
Single phase 230V ±10% - 50/60Hz
230V closing contact.
Brightness function.
Types of loads allowed:
Incandescent lamps/halogen lamps: 2300W.
Fluorescent lamps (electronic ballasts): 600W.
Fluorescent lighting (low loss ballast):
- uncompensated: 1150VA
- series compensated: 600VA
- parallel compensated: 400W
Compact fluorescent lamps (electronic reactor): 150W.
LED lamps: 400W (cosɸ ≥ 0.9).
Dry closing contact. Minimum load 10mA.
Maximum cutting capacity: 50VA (2A max) at 250Vac / 50W at
30Vdc.
Brightness independent.
Lighting output = brightness threshold adjustable from 5 to 1000
lux / decay delay adjustable from 15s to 30min.
Ventilation output = adjustable on delay from 0 s to 10 min / on
delay rain adjustable from 10 s to 120 min.
-25 a 55°C, max. 90% RH without condensation
CPTA-E N
(embedded into a false ceiling)
2,5 - 3,5m
360°
0,5W
54
Class 2
0,75 to 1,5 mm²
White plastic casing