Fitting into wall cupboard
Note: The extractor hood housing can be
clad inside the wall cupboard (e.g. with
chipboard).
If so, observe the following:
The intermediate base must not be
placed on the extractor hood housing.
Never attach cladding to the housing.
Provide access for customer service.
If the extractor hood is to be installed
further back in the cupboard, the stops
for the filter drawer can be moved
forwards.
To do this, undo the screws, move the
stops and retighten the screws.
Re-adjusting the limit switch:
1. Check whether the extractor hood
switches off when the filter drawer is
inserted.
2. If the extractor hood does not switch off,
re-adjust the limit switch.
3. Unscrew the screw in small steps –
max. 2 revolutions.
32
Moving the operating unit:
See Operating instructions.
Attaching the handle moulding:
A handle moulding must be attached to
the filter drawer.
This handle moulding may be a wooden
strip which matches the kitchen units or a
handle moulding available as an optional
accessory.
1. Using the enclosed template
the attachment points on the wooden
strip and make holes with a bradawl.
When you drill:
2 mm dia – max. 10 mm in depth.
2. Align handle
moulding
and screw
to the
appliance.
Do not
pinch the ribbon
cable.
O
, mark
III