1
YEAR
WARRANTY
CONTROLS & INDICATORS
1. Power Switch: is on back side of machine.
2. Potentiometer Knob: Allows you to adjust the current from 15 to 40 Amps.
3. Green LED Light: When illuminated, means the Plasma Cutter is on.
4. Yellow LED Light: When illuminated, means cutting is in process.
5. Red LED Light: When illuminated, means the Plasma Cutter has be¬come overheated and the unit
will automatically shut down. Stop using the Plasma Cutter while leaving the Power Switch ON to
allow the Cooling Fan to operate. The LED Light will turn off automatically when the unit cools
down and then you may resume cutting.
OPERATING INSTRUCTIONS
Read the entire Important Safety Information section at the beginning of this manual including all text under
subheadings therein before set up or use of this product.
Warning To prevent serious injury from accidental operation:
Turn the Power Switch (11) to its "OFF" position before performing any inspection, maintenance, or cleaning
procedures.
Work Piece and Work Area Set Up
1. Designate a work area that is clean and well-lit. The work area must not allow access by children or pets
to prevent injury and distraction.
2. Route the Power Cord along a safe route to reach the work area without creating a tripping hazard or
exposing the Power Cord to possible damage. The Power Cord must reach the work area with enough
extra length to allow free movement while working.
3. There must not be hazardous objects, such as utility lines or foreign objects, nearby that will present a
hazard while working.
4. A barrier, such as a welding curtain or welding shroud should be put up to protect others in the work area
and limit the spray of sparks.
GENERAL OPERATING INSTRUCTIONS
Warning. Protective gear must be worn when using the Plasma Cutter. Arc shaded, eye protection, a full
face shield, heavy-duty work gloves, a welding apron, respirator, and heavy-duty work clothes without
pockets should be worn when using this product. Do not look at the ignited arc without eye protection. Light
from the arc can cause permanent damage to the eyes. Light from the arc can burn the skin. Do not breathe
arc fumes.
1. IMPORTANT: The duty cycle defines the number of minutes, within a 10 minute period, during which a
given Plasma Cutter can safely produce a particular current.
• This Plasma Cutter is equipped with an internal thermal protection system to help prevent damage to
the unit. When the unit overheats; it automatically shuts down, then returns to service when it cools
down.
14