WDH 601-1501 SBS
Fittingthethermalinsulation
ENGLISH
1.
General information
1.1
Relevant appliances
Thermal insulation
WDH 601 SBS, part number 231925
WDH 801 SBS, part number 231926
WDH 1001 SBS, part number 231927
WDH 1501 SBS, part number 231928
As an accessory for the following instantaneous water heaters
SBS 601-1501 W | SBS 601-1501 W SOL
Note
Observe the operating and installation instructions pro-
vided with the appliance.
1.2
Further applicable documents
Operating and installation instructions Instantaneous
water heating cylinder SBS 601-1501 W | SBS 601-1501 W
SOL, part number 290021
2.
Fitting the thermal insulation
11
10
1 Cover
2 Top thermal insulation section
3 Top thermal insulation ring
4 Cover strip
5 R.h. thermal insulation section
6 Terminal cover
7 Terminal cover, electric emergency/booster heater
8 Thermal insulation section, bottom
9 Thermal insulation ring, bottom
10 Rose
11 Left thermal insulation section
www.stiebel-eltron.com
f On cylinders supplied horizontally, insert the bottom thermal
f Surround the support ring with the bottom thermal insula-
f Prior to fitting them, shape the right hand and left hand ther-
f Push the thermal insulation sections over the connections on
f Connect the thermal insulation sections at the front by clip-
f Position the thermal insulation sections around the cylinder
f Adjust the thermal insulation sections on the appliance by
1
f Starting from the top, retighten the hook closure strip from
2
4
3
f Place the upper thermal insulation ring and the upper ther-
5
f Place the cover over the thermal insulation sections.
6
f Fit the cover strips onto the hook closure strips. If required,
7
f Fill the hollow spaces near the connections with the soft
f Push the roses into the apertures.
8
f Insulate surplus connections with the terminal covers. Push
9
insulation section inside the support ring, prior to position-
ing the cylinder. Slightly tip the vertically delivered cylinder
in order to position the bottom thermal insulation section.
tion ring and secure it with adhesive tape.
mal insulation sections into a semi-circular form for approx.
10 seconds. A pressure-activated adhesive then holds the
thermal insulation sections in the required shape and makes
fitting them easier.
Please note that the use of tensioning straps may damage the
thermal insulation.
the appliance.
ping the hook closure strip into the last hook strip. If neces-
sary, the short black cover strips can be used to temporarily
hold the hook closure strips together.
and connect the thermal insulation sections at the back by
clipping the hook closure strip into the first or second hook
strip.
patting and pressing them down with the palm of the hand.
the top until it hooks into the final hook strip.
mal insulation section on top.
the cover strips can be trimmed to size.
foam inserts.
the terminal cover firmly onto the cover strip.
Note
f Affix the additional type plate in a clearly visible po-
sition on the thermal insulation.
WDH 601-1501 SBS|
3