50
XH06-1 Relay output
module function setting
The buzzer sounds when the
door opening, but does not sound
when the door closing.
The buzzer sounds when the
door closing, but does not sound
when the door opening
The buzzer sounds when the
door drive is running, whether it's
opening or closing
The buzzer turns o .
The buzzer turns o . (default)
Remark:
- Press and hold SET button for
about 6 seconds to enter main
menu until "0.-" appears on the
display then release the button.
- Press "+" till "6.-" appears on the
display.
- Press SET then appears "6.0" on
the display
- Press "+" till "6.6" appears on the
display.
- Press SET enter into XH06-1 Relay
output module function setting.
(Refer
to page - 36 Relay module output
terminal)
Reach the open limit position, relay
closed
Reach the close limit position, relay
closed
Reach the partial open limit
position, relay closed