13
If it is decided to mount the heater on the wall, the feet should not be mounted. The position
must be carefully selected. It should not be in front of or under an electrical outlet. It should
not be under a shelf, curtains or other obstacles. Also observe the safety instructions.
After deciding on the location of the heater, you need to drill 4 mounting holes with a
diameter of 8 mm and a depth of 4 0 mm, the position and size see the following figure. You
need to consider the floor coverings, carpets, etc. And if skirting boards are present, the
mounting holes should be at least 1 0 0 mm above the top edge of the socket or floor. Attach
2 of the mounting brackets to the wall with the supplied plastic pins and mounting screws. The
other pair of clamp brackets should be attached to the base of the heater with the foot
locking screws so that the brackets protrude from the back of the heater and the bottom
edge is placed away from the wall.
If necessary, these brackets can also be attached to the wall with the new mounting screws
and plastic pins. If this option is selected, it is recommended to hang the heater on the top
brackets and mark the hole positions for the lower brackets on the wall before drilling the
holes for mounting purposes. See the pictures below.
Position and size
www.eshopping.de
Hergestellt für Dilaw Warehouse GmbH // Fuggerstraße 15a // 48165 Münster // Germany