Simplified Eu Declaration Of Conformity - Bentel Security ABSOLUTA T-Line Manual De Instalación E Información Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2) Programming the ADDRESS - Set the address of the keyboard (from 1 to 32),
then press ENTER to confirm the appearing address and move on to the next step
or press ESC to cancel the change and exit programming.
3) Programming the PROXIMITY READER - Press ON to enable the Proximity
Reader, then set the address of the Proximity Reader (from 1 to 32), then press
ENTER to confirm and move on to the next step or,
press OFF to disable the Proximity Reader, then press ENTER to confirm and move
on to the next step or,
press ESC to cancel the changes and return to the preceding step.
4) Programming the INPUT EXPANDER - Press ON to enable the Input Expander,
then set the address of the Input Expander (from 1 to 32) then press ENTER to
confirm and move on to the step no. 6 or,
press OFF to disable the Input Expander, then press ENTER to confirm and move
on to the next step or,
press ESC to cancel the changes and return to the preceding step.
The zones corresponding to terminals L4, L5 and L6 of the Keypad Input
Expander, although appearing on the application/display, CANNOT be used.
5) Programming the OUTPUT EXPANDER - Press ON to enable the Output
Expander, then then set the address of the Output Expander (from 1 to 16) or use
the keys C and D to scroll the addresses, then press ENTER to confirm and exit
programming or,
press OFF to disable the Output Expander, then press ENTER to confirm and move
on to the next step or,
press ESC to cancel the changes and return to the preceding step.
The outputs corresponding to terminals OC4, OC5 and OC6 of the Keypad Output
Expander, although appearing on the application/display, CANNOT be used.
It is possible to enable ONLY ONE of the two Espanders: either the Input or the
Output Expander. If you do not want to use any Expander, put in the value OFF
for both of them.
6) Programming of the ZONES - Press the keys 1, 2 or 3 to change the functioning
mode, of the corresponding zone, respectively, at terminal T1, T2 or T3, as shown
in the following table, then
press ENTER to confirm and exit from the programming or,
press ESC to cancel the changes and return to step no. 4.
If the Input Expander and the Output Expander have been disabled, it would be
possible to program only the functioning mode relative to terminal T1 and T2.
Programming of Zones
NORM
The zone functions in Norm al M ode
The zone operates in norm al m ode, or rather it enters alarm m ode on
the basis of the program m ed Sensitivity, and as an Interface for
FAST
Shutter Contact, or rather it enters alarm m ode w hen it detects 5
knocks in the space of 2 m inutes.
The FAST functioning mode (Roller blind) could be entered only with the proce-
dure described in these instructions, and not by software, through the Bentel
Security Suite application (the Roller blind Quality for the Zones related to the
Keypads Input Expander is blocked).
BRIGHTNESS, CONTRAST AND VOLUME
To adjust the brightness, the contrast and the volume of the internal buzzer, follow
the procedure described below:
BRIGHTNESS
It is possible to adjust the brightness of the keys and also the brightness of the
backlighting of the display.
It is possible to adjust the inactive and the active brightness (the inactive brightness
is the brightness to which the keypad reverts after 10 seconds of inactivity.
To adjust the active brightness, follow the procedure described below:
1a) To increase the brightness, press and keep pressed key A until the desired
level is obtained:
1b) To lower the brightness, press and keep pressed key B until the desired level
is obtained:
2) Press the OFF key to adjust the inactive brightness:
3a) To increase the brightness, press and hold down key A until the desired
brightness is reached:
3b) To reduce the brightness, press and hold down key B until the desired
brightness is reached:
4) Press the ON key to adjust the active brightness and return to step 1a), or press
the ENTER key to confirm the chosen levels, or
wait a few seconds for the keypad to return to the inactive state.
CONTRAST
To adjust the contrast of the LCD display, follow the procedure described below:
1a) To increase the contrast, press and keep pressed key D until the desired level
is obtained.
1b) To lower the contrast, press and keep pressed key C until the desired level
is obtained.
2) To confirm the chosen level, press the ENTER key (or wait a few seconds for the
keypad to return to the inactive state).
VOLUME
To adjust the volume of the internal buzzer, follow the procedure described below:
1) Press and keep pressed the ESC key; the internal buzzer will start sounding a series
of beeps in such manner that the operator could hear the sound level in real time.
NOTE - The buzzer will still emit a series of sound alerts at extremely low volu-
me, even if it has been set to zero.
2a) To increase the volume, press key A for a number of times and/or keep it
pressed until the desired level is obtained:
2b) To lower the volume, press più volte and/or keep pressed key B until the
desired level is obtained.
3) To confirm the chosen level, press the ENTER key (or wait a few seconds for the
keypad to return to the inactive state).
CONNECTIONS
The keypad should be connected to the BPI bus of the control panel as described
in the instructions delivered with the same control panel.
This Keypad supports ONLY a 12 V BPI level.
To connect the zones and the outputs (terminals T) refer to the control panel
installation manual.
To connect Contacts for Roller blinds refer to Fig.1: the Keypad zones in FAST
mode (Roller blind), can be programmed as Normally Closed (a), Balanced 10K (b)
and Double Balanced (c).
TAMPERING AND DISCONNECTION
When the keypad is opened or pulled off the wall, a tamper alert is generated for
all enabled and configured devices: Keypad Tamper, Motion Sensor Tamper, Input
Expansion Tamper, Output Expansion Tamper.
The keypad also generates a tamper alert every time it is activated, as follows (see
figure 2):
1.
if the Output Expansion is enabled, NO tamper alert is generated when
the keypad is activated;
2.
if the Input Expansion is enabled, an Input Expansion tamper alert is
generated;
3.
if the Input Expansion is NOT enabled, a Keypad tamper alert is
generated (if the keypad is connected to a KYO320, KYO300 or KYO100
control unit and has been configured).
When the keypad does NOT respond to the prompts of the control unit (due to a
lack of power, problems in bus communication, mismatched addresses, general
malfunctions), a BPI Device Disconnection alert is generated for all enabled and
configured devices: Keypad Disconnection, Motion Sensor Disconnection, Input
Expansion Disconnection, Output Expansion Disconnection.
SIMPLIFIED EU DECLARATION OF
CONFORMITY
Hereby, Bentel Security declares that the radio equipment type ABSOLUTA T-LINE
is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet
address: www.bentelsecurity.com/dc.

Publicidad

Tabla de contenido
loading

Tabla de contenido