E10
E11
Parameters
-
P01: Brightness (level 1 is the darkest and level 3 the brightest).
P02: Mileage unit, 0: KM; 1: MILE
-
-
P03: Voltage level: 24 V, 36 V, 48 V, 60 V, 64 V; default 36 V.
P04: Latency time. 0 indicates no latency. Any other number indicates latency time.
-
Range: 1-60 (minutes).
P06: Wheel diameter (inches). Precision: 0.1. This parameter is related to the speed
-
displayed on the console.
Note: the unit used is kilometres. When changing from kilometres to miles, the speed shown
will be in miles. However, the speed limit will not be changed to miles.
Note: programmes P09-P15 are only valid in communication status.
P09: Zero (and non-zero) start. 0 indicates zero start; 1 indicates other non-zero starts.
-
-
P11: Pedal fluidity range: 1-24.
P12: Gears: 0-5.
-
-
P14: The limit value of the controller is set to 12 A by default. Range: 1-20th
P15: Controller voltage setting.
-
-
P16: ODO. To set the value to zero, press and hold the button for five seconds.
P17: Cruising speed. A value of 0 means that it is not allowed to activate the cruising
-
speed. When activated, 1 will be displayed.
P18: Adjusting the size of the speed on the display (50%~150%).
-
-
P19: Assistance mode. If the number displayed in the assistance mode is 0, it means that
assistance is not activated. 1 means that assistance is activated.
-
P20:0:2 Protocol 1:5 S Protocol 2: Standby 3: Standby
Button operation
Press the
button to switch on the console. When it has been switched on, briefly press
-
the
button again to switch between ODO, DST, and TIME.
+
Press the
button and the PAS (Pedal Assist System) will increase by one level. Press
-
-
the
button and the PAS will decrease by one level.
+
Long press the
-
-
If the bike is parked, when the display shows the speed display area, press, and hold the
button to enter the start mode at standstill (6 km/h).
-
Press and hold the
button to switch the headlight on or off.
+
-
and
buttons to go to the settings.
Data reception failure
Data sending failure
ENGLISH
-
87
MOUNTAIN VENTUS