CONFIGURATION MENU STRUCTURE
CONNECTIVITY MODULES
Your GYSFLASH is equipped with a DB9 type socket allowing you to connect various additional modules offered by GYS such as a
printer, Ethernet or other module in order to further extend the possibilities of your charger.
LIST OF ERROR CODES
Error code
Err01: Int_1 - Err02: Int_2
Err23: Int_3 - Err24: Int_4
Err03: Fuse_NOK
Err04: T>Tmax
Err05: (+)(-)
Err06: U>__V
Err07: No_bat
Err08: U<__V
Err09: U>__V
28
Translation of the original
instructions
Language selection
Date/time selection
Sound On / Off
Traceability
Automatic or Manual
Cable calibration
Cable calibration
Automatic
Manual
Automatic or Manual
Informations
Meaning
Electronic problem
Defective charger
Output fuse out of order
Abnormal overheating
The polarity has been reversed on the
clamps
Overvoltage detected at the clamp terminals Disconnect the clamps
Battery not connected
Abnormally low battery voltage
Abnormally high battery voltage
Explore data
Export data
+ Options
Portability
Multi-charger
Contact the reseller
Have the fuse replaced by a qualified person
Contact the reseller
Connect the red clamp to the (+) and the black clamp to the (-) of
the battery.
Check that the battery is correctly connected to the charger
Check that the selected mode is compatible with the battery
voltage (e. g. : 6 V battery in 24 V mode)
Charge the battery via CHARGE mode
Battery to be replaced
Check that the selected mode is compatible with the battery
voltage (e. g. : 24 V battery in 12 V mode)
GYSFLASH 107.24 CNT FV
Restore CONFIG
Import CONFIG
Export CONFIG