Installation
6
Strainer and Drain Cap
Faucet and soap removed for clarity.
Drain cap is labeled front and back. Be sure front
is facing the user. Top surface of drain cap should
be sloped away from user.
1 station shown, 2 station similar.
Position drain cap over
trough strainer, aligning
tabs into drain. Push
A
drain cap down until drain
cap is flush with basin.
Grommets should hold
drain cap securely against
drain tough walls.
To remove drain cap,
carefully slip flat
B
screwdriver into left or
right hand corner of
drain cap and gently lift
upwards.
7
Adjust Temperature with Water Running
WARNING This valve is NOT factory preset. Upon installation, the
temperature of this valve must be checked and adjusted
to ensure delivery of a safe water temperature. Water in
excess of 110°F (43°C) may cause scalding.
A
Loosen cap screw about ¹⁄₄" (4–6 turns)
and lift up cover (do not remove).
Using cover, turn cartridge gently until
B
desired water temperature is reached.
Do not turn past stops as this may
damage unit. Push cover down and
tighten screw.
Bradley • 215-1850 Rev. G: ECO 22-08-019
Front
C
H
Note the angle of
the drain cap.
6/1/2022
LVAD2