TROUBLESHOOTING
Problem
Control panel does not illuminate.
Control Panel is on but nothing
happens after closing the lid.
Lid does not open automatically.
Final vacuum is not sufficient.
Machine extracts air too slowly.
Vacuum bag is not sealed correctly.
SERVICE AND REPAIR
Serviceable parts are available on vollrathfoodservice.com.
To avoid serious injury or damage, never attempt to repair the unit or replace a damaged power cord yourself. Do not send units
directly to The Vollrath Company LLC. Please contact Vollrath Technical Services for instructions.
When contacting Vollrath Technical Services, please be ready with the item number, model number (if applicable), serial number, and
proof of purchase showing the date the unit was purchased.
WARRANTY STATEMENT FOR THE VOLLRATH CO. L.L.C.
This warranty does not apply to products purchased for personal, family or household use, and The Vollrath Company LLC does not
offer a written warranty to purchasers for such uses.
The Vollrath Company LLC warrants the products it manufactures or distributes against defects in materials and workmanship as
specifically described in our full warranty statement. In all cases, the warranty runs from the date of the end user's original purchase
date found on the receipt. Any damages from improper use, abuse, modification, or damage resulting from improper packaging during
return shipment for warranty repair will not be covered under warranty.
For complete warranty information, product registration, and new product announcements, visit vollrathfoodservice.com.
vollrathfoodservice.com
Potential Cause
•
Machine is not plugged in.
•
Main fuse is burned out.
•
Circuit board fuse is burned out.
•
Lid micro switch might need adjusting.
•
Control transformer fuse is burned out.
•
Gas spring is damaged.
•
Lid micro switch might need adjusting.
•
Pump might be damaged.
•
Lid might not have opened correctly.
•
Machine has reached a scheduled oil change.
•
Pump conditioning program needs to run.
•
Set vacuum time is too short.
•
Extraction hole at vacuum chamber back is partially
covered by the vacuum bag during extraction.
•
Lid gasket is worn.
•
There is too little oil in the vacuum pump.
•
Oil is contaminated.
•
Oil exhaust filter is saturated.
•
Oil exhaust filter is saturated.
•
Pump's extraction filter is blocked.
•
Vacuum bag is placed incorrectly on the Sealing Bar.
•
Sealing time is too long or too short.
•
Seal pad is damaged or worn.
•
Teflon tape is damaged.
•
Vacuum bag opening is not clean.
The Vollrath Company, L.L.C.
1236 North 18th Street
Sheboygan, WI 53081-3201 U.S.A.
Main Tel: 800.624.2051 or 920.457.4851
Main Fax: 800.752.5620 or 920.459.6573
Customer Service: 800.628.0830
Canada Customer Service: 800.695.8560
© 2024 The Vollrath Company L.L.C.
Course of Action
•
Plug the machine in.
•
Contact Vollrath® Technical Services.
•
Check the lid.
•
Contact Vollrath Technical Services.
•
Refer to the Cleaning section of this manual.
•
Extend the vacuum time.
•
Place the vacuum bag closer to the sealing bar.
•
Replace the lid gasket.
•
Contact Vollrath Technical Services.
•
Place vacuum bag on sealing bar, ensuring the
opening is within the vacuum chamber and the bag
is smooth.
•
Adjust the sealing time.
•
Replace the seal pad.
•
Replace the Teflon tape.
•
Clean the vacuum bag's opening.