ADURO H1 Manual De Usuario página 51

Ocultar thumbs Ver también para H1:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 89
thin gasket is placed between the flue pipe and the pipe sleeve to seal the joints. The flue pipe should
protrude 5–10 cm into the pipe sleeve, but must not block the opening in the chimney (see the illustration
below).
X
The Aduro H1 can be connected to a chimney to which other heat sources are connected.
2.4 Supply of combustion air
When a stove is installed in a room, the demand for air supply
in the room raises. See point 3.9. Air from outside can be
provided through a channel, which is connected to the
connecting pipe under the combustion chamber. The amount of
air needed for combustion is 25m3/h.
The connecting pipe has an external diameter of 78 mm, to
which you need a pipe with a diameter of 80 mm. If the pipe
work is further than 1 m the pipe diameter must be increased to
100 mm and a correspondingly larger wall valve must be
chosen. In warm rooms the channel should be insulated with 30
mm mineral wool covered with a damp-proof course (plastic). It
is important that the lead-in between the pipe and the wall (or
floor) is sealed with jointing compound. You can eventually use
the complete Aduro fresh air kit.
2.5 Connection to App – control
It is possible to control Aduro H1 in three ways:
1. Via the control panel on the stove
2. Via the app Aduro Hybrid 1 in the immediate vicinity of the stove
3. Via the app Aduro Hybrid 1 connected to Aduro Cloud. When your stove is connected to Aduro
Cloud, it is connected to the internet and can be controlled remotely
Access to the Aduro Hybrid 1 App is free, and it can be downloaded from App Store or Google Play. The app
is compatible with IOS versions from 5S and Android versions from 4.1.
51

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

En13240En14785Ns3058

Tabla de contenido