RUNTAL FOLIO GLASS
IMPORTANT This appliance should never be
installed with the electrical connection box
positioned topside.
IMPORTANT The example shown only concerns
a bathtub. For other bathroom fixtures, please
consult your installer.
CAUTION Always turn off the electricity supply
(circuit-breaker + pilot wire) before making any
connections.
2.3 CONNECTING THE APPLIANCE
The technical specifications of your radiator are shown on its name-
plate.
Please note these down before installing it and before requesting any
after-sales ssistance.
IP: protection level of your appliance
against the ingress of solid foreign
bodies and water spray
xxxV xxxxW: voltage and power
required for installation
Appliance reference number
Serial number
When connecting the appliance to the mains, you must observe:
• The voltage indicated on the nameplate
• Conventional colour coding:
- blue or grey: neutral
- brown: live
30
RUNTAL
IP 45
230V-50Hz XXXXW
FGW-XXX-XXX/X
Serial no.: XXXXXXXXXX
Cat. XXX Type: XXXXX
- black: pilot wire (France)
- green and white: ground termi-
nal (Switzerland)
40016966
CONNECTING PRINCIPLE WITH PILOT WIRE :
Your appliance is equipped with a pilot wire for connection to a pilot
wire programming base unit (not supplied with the appliance).
N (blue or grey)
L (brown)
Pilot wire (black)
Note: Your appliance is equipped with an integrated electronic
control system so we cannot accept any liability should the appliance
be used with Pilot Wire programming base units that function by
disconnecting the supply voltage (refer to the instructions supplied
with your control unit).
CONNECTING PRINCIPLE WITHOUT PILOT WIRE:
If the pilot wire is not connected, it must be insulated for safety rea-
sons. Under no circumstances must it be connected to earth.
N (blue or grey)
L (brown)
Pilot wire (black)
CONNECTION SYSTEM WITH MAINS PLUG
READY-FITTED:
For other countries (apart from France), the
appliance must be installed in accordance
with standards in force and with rules of
good professional practice in the country of
use.
The flexible cable supplied with the appliance
is designed to be connected to the mains via
a plug.
40016966
ENGLISH
Neutral
Live
Pilot wire (base unit)
Neutral
Live
Switzerland
Europe
31