RUNTAL FOLIO GLASS
4 USING YOUR APPLIANCE WITH THE
CONTROL PANEL
4.1 OVERVIEW
The Runtal radiators are equipped with an advanced control system
with touch-screen controls and light indicators which indicate the set
function.
Changes in settings are also remarked by an acoustic signal.
Control panel with symbols and functions
Touch
Function
screen
T1
STAND-BY
Low-temperature heating
T2
(45°c)
Medium-temperature heating
T3
(55°c)
Maximum-temperature
T4
heating (65°c)
Maximum-temperature
T5
2-hours boost
T6
Keypad Lock
Red LED indicates radiator is
heating up
Appliance in tension
34
LED
L1
T1
L1
L2
T2
L2
L3
L3
T3
L4
L4
T4
L5
L6
L5
T5
L7
L8
L6
T6
L7
L8
40016966
4.2 USE
When connecting the power supply, all the LEDs light up for
2 seconds and you will hear a long "beep". After this, only L1
and L8 will remain on.
Touch T2 if you wish to heat up the room at low temperature.
The L2 and L7 green LEDs will light up and you will hear a
"beep". When the surface of the radiator reaches the set tem-
perature, L7 switches on and off cyclically in order to maintain
the set temperature.
Touch T3 if you wish to heat up the room at medium tempera-
ture. The L3 and L7 green LEDs will light up and you will hear a
"beep". When the surface of the radiator reaches the set tem-
perature, L7 switches on and off cyclically in order to maintain
the set temperature.
Touch T4 if you wish to heat up the room at maximum tem-
perature. The L7 green LED will light up and you will hear a
"beep". When the surface of the radiator reaches the set tem-
perature, L7 switches on and off cyclically in order to maintain
the desired temperature.
Touch the T5 button if you wish to have the maximum surface
temperature for a limited time (2 hours), the L5 and L7 LEDs
will light up. The radiator will operate at maximum temperature
for 2 hours, after which, it will go back to operate in the func-
tion set before the Boost function.
If after the settings you wish to lock the keypad, press the T6
button for 5 seconds - you will hear 4 beeps confirming the
setting.
When touching the other buttons lightly, the L6 LED will flash
for 2-3 seconds indicating the keypad is currently locked.
Only the T1 button will remain operational, so to put the appli-
ance on stand-by at any time.
To reactivate the keypad, press the T6 button for 5 seconds -
4 consecutive beeps will confirm the setting.
40016966
ENGLISH