- the room in which the compressor is running is not too cold (below
0°C)
- the electric line is effi cient (plug connected correctly, magneto thermal
switch, fuses not blown)
The compressor fails to stop (only with tank)
if the compressor fails to stop when the maximum pressure is reached,
the tank safety valve will trip. Contact the nearest authorised service
centre for the repairs.
WARNING
- Do not unscrew any connections with the tank when under pressure
for any reason whatsoever. Always make sure that the tank is de-
pressurised beforehand.
- Do not drill, weld or intentionally deform the compressed air tank.
- Do not carry out any operations on the compressor before it has been
unplugged from the power socket.
- The room temperature for its correct effi ciency is: 0°C +25°C (MAX
45°C).
- Do not direct jets of water or flammable liquids over the
compressor.
- Do not place fl ammable objects near the compressor.
- When stopped temporarily during its use, turn the pressure switch or
the ON/OFF switch to position «0» (OFF) (turned-off).
- Never direct the jet of air towards people or animals (fi g. 24).
- Do not transport the compressor when the tank is pressurised.
- Be aware that some components of the compressor such as the head
and delivery hoses may reach high temperatures, therefore do not
touch the to avoid getting burned (fi g. 10).
- Transport the compressor by lifting or pulling it with the appropriate
grips or handles (fi g. 5 - 6).
- Children and animals must be kept away from the area in which the
machine is running.
If the compressor is used for painting:
a) Do not work in closed areas or near free fl ames
b) Make sure that the area in which you are working has a good
change of air
c) Protect nose and mouth using an appropriate mask (fi g. 18).
- Do not use the compressor if the electric cable or the plug is
damaged.
- Contact the nearest authorised service centre for the replacement
with an original component.
- If it is placed on a shelf or a surface that is raised off the ground,
it must be secured appropriately to prevent it from tipping off when
running.
- Do not insert objects or your hands inside the safety grating to avoid
physical damage and also damage to the compressor (fi g. 19).
- Do not use the compressor to threaten people or animals to avoid
serious injuries.
- Always unplug the compressor from the power socket when you have
fi nished using it.
ELECTRIC COMPRESSOR MODEL (GMS-VS-AIRCLIK-F 1)
Maximum running pressure: 8.5 bar
Maximum working pressure: 8 bar
NOTE:
The compressor tanks have been manufactured in compliance with the
87/404/EC Directive for the European market.
The compressors have been manufactured in compliance with the
98/37/EC Directive for the European market.
The measured sound pressure level measured in a free range at a
distance of 1 m: ±3dB(A) at the maximum working pressure. (table 3)
20
F SERIES
HP/KW
1/075
1.5/1.1
1.5/1.1
2/1.5
GMS SERIES
HP/KW
0.75/0.55
1.5/1.1
1.5/1.1
VS SERIES
HP/KW
2/1.5
2/1.5
3/2.2
The value of the sound level may increase from 1 to 10 dB(A) depending
on the room in which the compressor is installed.
HINTS FOR EFFICIENT OPERATION
THE F1 & AIRCLICK COMPRESSORS HAVE BEEN DESIGNED FOR INTERMIT-
TENT USE, THESE MODELS SHOULD ONLY BE USED FOR APPLICATIONS
WHERE USAGE WILL NOT EXCEED 25% OF DUTY OVER THE COURSE OF
ONE HOUR.
PNEUMATIC CONNECTIONS
Make sure you always use pneumatic tubes for compressed air
with maximum pressure characteristics that are adequate for the
compressor.
Do not attempt to repair tubes if faulty.
WE RESERVE THE RIGHT TO MAKE ANY MODIFICATIONS WITHOUT
PRIOR NOTICE WHENEVER NECESSARY.
RPM
dB(A)
1450-1750
65
2850
77
3450
80
2850
78
RPM
dB(A)
1450-1750
77
1450-1750
77
2850
78
RPM
dB(A)
1450
77
1750
80
2850
82