F a u l t D i a g n o s i s
S y m p t o m
P o s s i b l e C a u s e
More than one
Air leak
operation of the
Insufficient air pressure
trigger needed to
Worn or broken jaws
place fastener
Low oil level or air in oil
Build up of dirt inside the nose assembly
Tool will not grip
Worn or broken jaws
stem of fastener
Build up of dirt inside the nose assembly
Loose jaw housing or chuck collet
Weak or broken spring in nose assembly
Incorrect component in nose assembly
Jaws will not release
Build up of dirt inside the nose assembly
broken stem of
chuck collet.
fastener
Weak or broken spring in nose assembly
Air or oil leak
Low oil level or air present in oil
Cannot feed next
Broken stems jammed inside tool
fastener
Slow cycle
Low air pressure
Build up of dirt inside the nose assembly
Tool fails to operate
No air pressure
Damaged Trigger Valve 46
Loose stem collector
Fastener fails to break Insufficient air pressure
Fastener outside tool capability
Low oil level or air present in oil
Tool fails to swage
Insufficient air pressure
collar
Worn or damaged anvil
Low oil level or air present in oil
Item numbers in bold refer to the General Assembly drawing and Parts List on pages 16-17.
Other symptoms or failures should be reported to your local Avdel
20
R e m e d y
Tighten joints or replace components
Adjust air pressure to within specification
Fit new jaws
Prime tool
Service
Fit new jaws
Service
Tighten against locking ring
Fit new spring
Identify and replace
Service
Tighten nose assembly
Fit new spring
Tighten joints or replace components
Prime tool
Empty stem collector
Check correct equipment is fitted
Adjust air pressure to within specification
Adjust air pressure to within the specification 5
Service
Connect and adjust to within the specification 5
Replace
Tighten Retaining Nut 26
Adjust air pressure to within specification
Use more powerful Genesis tool.
Contact Avdel UK Limited
Prime tool
Adjust air pressure to within specification
Replace
Prime tool
®