23.2.2. REGULATION CUT OF THE MACHINE PRESS

The cut of the machines press are adjusted in the beginning, but if you felt it
didn't cut the way it should, the cut of the machine press will have to be in
order with the surface of the transporting band.
This will open the speed setting of the guillotine to the minimum we can
launch the machine, and stop when we see that the blade is in its lowest
position
VERY IMPORTANT: watch out there is no object under the slicer before
pressing the button. Don't put your hand or any part of your body near the
slicers while it is on movement.
B
Through the nuts "A" we can regulate with a 17mm wrench the height of each
of the extremes of the wound until it is completely at the same level than the
transporting band, and the thick of the band and of the guillotine have to be
equivalent to a fine paper.
To adjust the distance or angle of the oblique cutting blades, loosen the
screws B with 6mm Allen wrench, placed in the position and angle.
IMPORTANT: this operation will just be made by qualified personal for the
maintenance and reparation operations.
IMPORTANT: leaving the machine press to low will block the good function of
the guillotine and it will cause damage on the transporting band.

23.2.3. CHANGE OF THE AXIS SLICER

A
Page 51
H.BERDER 10/04/2012