54 TROUBLESHOOTING
Error Codes
Problem
Error code: tE1 through tE7
Display shows error code: PS
*Flow Sense™ indicator shows
four bars during the drying cycle
or the display shows "d80" after
drying
* This warning light is not a dryer
failure and is not covered by the
dryer warranty. Contact a duct
cleaning service to set up an
appointment to have your exhaust
system cleaned and inspected.
The Flow Sense™ indicator
remains active after clearing the
restriction in the venting.
The display shows
The display shows
Check filter indicator is on during
the drying cycle
Possible Cause
Temperature sensor
failure.
Power cord is connected
incorrectly.
Exhaust system is too
long or has too many
turns/restrictions.
Partial blockage of the
ductwork due to lint
buildup or other foreign
object.
The appliance has
detected a restriction
in the external dryer
venting.
After clearing the
restriction, the Flow
Sense™ system requires
multiple, consecutive
cycles to determine that
the performance value
has improved before the
Flow Sense™ indicator
is reset.
More Time button was
pressed.
The duct work is about
75% - 95% blocked.
("d75", "d80", "d90"
or "d95" error code is
displayed for 2 hours
only)
House exhaust system
blocked.
Lint filter not cleaned
properly.
Solutions
• Turn off the dryer and call for service.
• Check the connection of the power cord to
the terminal block.
• Install a shorter or straighter duct run. See
the Installation Instructions for details.
• Ductwork should be checked/cleaned
immediately. Dryer can be used in this
condition, but drying times will be longer and
energy consumption will increase.
• If exhaust restrictions are sensed by the Flow
Sense™ system, the indicator will remain
on for 2 hours after the end of the cycle.
Opening the door or pressing the Power
button will turn off the display.
• If the Flow Sense™ indicator remains active
for more than five cycles after the restriction
has been cleared, call for service.
• This display indicates that the steam option
has been set for a "big" item such as a
comforter.
Press the LESS TIME button to reduce the
indicated load size.
• Do not use the dryer until the exhaust system
has been cleaned and/or repaired. Using the
dryer with a severely restricted exhaust is
dangerous and could result in a fire or other
property damage.
Check the outside dryer vent while the dryer
is operating to make sure there is strong
airflow.
If the exhaust system is extremely long, have
it repaired or rerouted.
• Keep the area around the dryer clean and
free of clutter.
Check vent hood for damage or lint clogging.
Make sure the area around the vent hood is
clear.
• Remove the lint from the filter before every
load. With the lint removed, hold the filter up
to a light to see if it is dirty or clogged. If it
looks dirty, follow the cleaning instructions.
With some loads that produce high amounts
of lint, it may be necessary to clean the filter
during the cycle.