Installation Recommendations; Maintenance; Lubrication - Nidec ORTHOBLOC 3000 Instrucciones Para La Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1 - INSTALLATION
RECOMMENDATIONS
Installation must be performed by qualified personnel. Allow
sufficient room around the geared motor for plugs (or vessel)
accessibility:
- 200 mm: G1/4'' plug for Ot 31 to Ot 35.
- 500 mm: G3/4'' dipstick for Ot 36 to Ot 39.
1/4 H min.
Gearbox:
For the installation of Orthobloc 3000 gearbox, follow the
"Recommendations" chapter in the general manual.
If the gearbox is fitted with a MU universal mounting with a stiff
coupling by key, we recommend the application of a lithium
paste (molykote TP42 or equal) on the motor shaft.
Motor:
For connection of the complete drive system (with brake),
follow the instructions of corresponding maintenance delivered
with the goods in the parcel.
Gearbox nameplate:
1 - gearbox model and size
2 - operating position
3 - fixing type (S with foot, BS, BDn or SBT...)
- possible options
4 - exact ratio
5 - serial number
6 - lubricant
4
1
Ot 3333 B3 S
793 254 602 / 002
113
i
MIN EP ISO VG 220

2 - MAINTENANCE

Control after commissioning (50 hours of operation).
Check tightening of fastening screws and belt tensioning if
applicable.
Preventive maintenance visit.
- Check regularly that the recommendations concerning
mechanical and electrical installation are still complied with.
- If the gearbox is fitted with a breather plug, make sure that the
vent hole of the plug is not obstructed.
- Inspect the seals.
- Clean the ventilation louvers of the motor.
- Lubricate the bearings of the motors fitted with grease
nipples.
- Control the air gap of brake motors.
Installation guide - ORTHOBLOC 3000
3996 en - 2019.12 / o
DRIVE SYSTEMS - ORTHOBLOC 3000
5
2
3
12,8
min
-1
6
Oil, seals, bearings, AD
Adjust oil level.
6 months
Inspect the seals.
Drain and refill mineral oil.
3 years
Change the seals.
(or 5 000 h)
Change the grease of regreasable
bearings.
Drain and refill synthetic oil.
5 years
Change the seals.
(or 25 000 h)
Change the grease of regreasable
bearings.
Grease nipple on AP Ot 35
- Replace the grease ISO VG 100, NLGI 2, after 12 000 h
(25°C; 1500 min
)
-1
AP can be commissioned without
< 1 year
regreasing.
Storage
> 1 and < 2
Regrease before commissioning.
period
years
Dismantle AP. Clean it.
2 to 5 years
Replace the grease completely.

3 - LUBRICATION

For operation in ambient temperature between -10°C and
+40°C, Orthobloc 3000 reducer is shipped, as standard, with
mineral Extreme Pressure oil : MIN EP ISO VG 220.
From -30°C to +60°C: synthetic oil PAO ISO VG 150.
From -30°C to -10°C: synthetic oil PAO ISO VG 32.
From -30°C to +60°C and for use in the food industry: synthetic
oil PAO H1 ISO VG 150.
You must use an oil of the recommended type.
Polyglycol lubricants cannot be mixed with mineral or synthetic
lubricants of a different type.
Oil capacities.
The oil capacities shown in table (see § 3.2 to § 3.4) are
approximative values and should be used only as reference in
determining how much oil to provide. The proper oil levels can
only be determined by:
- Ot 31 to Ot 35: plug: filling the reducer to the level of the
plug,
- Ot 36 to Ot 39: dipstick (J): adjust oil level between the 2
marks (up/down).
9

Publicidad

Tabla de contenido
loading

Tabla de contenido