Dear Sir/Madam
Thank you for choosing Pellinsert 54.
Before using the insert, please read this information carefully. It is important for an optimal, safe use of all product characteristics.
Please do not hesitate to contact your local retailer for any clarification or other requirements. Alternatively visit the Dealer.
Remember that the very first ignition MUST be carried out by a Dealer, who will check installation and calibrate as necessary (stan-
dard UNI 10683 rev. 2005), in addition to completing and activating the warranty.
All incorrect installation, incorrectly performed maintenance or improper use of the product relieves the manufacturer from any
liability for damages deriving from use.
SAFETY INFORMATION
• PELLINSERT 54 has been designed to heat the room it stands in by radiation and air movement.
The hot air is released from the front part of the insert indirectly, making for great user comfort.
• The only risks that may derive from insert use arise through lack of compliance with installation regulations, direct
contact with powered electrical parts (internal), contact with the fire or hot parts (glass, pipes, hot air output), or from the
introduction of items into the hearth.
•Only use wood pellets with 6 mm diameter, as fuel.
• Should a failure occur, the insert is equipped with safety devices to guarantee its automatic switch-off.
This entails no efforts by the user.
• For correct function, the insert must be installed in compliance with the instructions given on this technical sheet.
• The door must not be opened during function: combustion is fully automatic and requires no manual intervention.
• Only use pellets as fuel: under no circumstances should any other substances be introduced into the hearth or tank.
• Do not use flammable products to clean the smoke paths.
• Only use a vacuum cleaner to clean the parts of the hearth and tank.
• Glass can be cleaned COLD with a specific product (e.g. GlassKamin) and a cloth. Do not clean when hot.
• The insert must be laid and ignited by an EDILKAMIN Dealer, authorised to fill out the warranty. These are the only
conditions under which the warranty will be validated.
• During insert function, the exhaust pipes and door become very hot (inform children).
• Do not place any objects that are not heat resistant in the immediate vicinity of the insert. See minimum distances as
given on page 25.
• NEVER use liquid fuels to ignite the insert or revive cinders.
• Do not block ventilation apertures in the installation room, nor the insert air intakes.
• Do not bathe the insert. Do not approach electrical parts with wet hands.
• Do not use reducers on the smoke exhaust pipe.
• The insert must be installed in rooms suitable for fire prevention and equipped with all services (supply and discharges)
required by the appliance to function correctly and safely.
Should ignition fail, DO NOT re-ignite until you have emptied the combustion chamber.
The undersigned EDILKAMIN S.p.a. with head offi ce headquarters at Via Vincenzo Monti 47 - 20123 Milan - Italy - VAT T00192220192
Declares under its own responsability as follows:
The wood pellet fireplace illustrated below conforms to Regulation EU 305/2011 (CPR) and to the harmonised European Standard
EN 14785:2006
WOOD PELLET FIREPLACE, trademark EDILKAMIN, called PELLINSERT 54
Year of manufacture:
Ref. Data nameplate Declaration of performance (DoP - EK 038):
In addition, it is hereby declared that:
the wood pelletfireplace PELLINSERT 54 is in compliance with the requirements of the European directives:
2006/95/EC - Low voltage directive
2004/108/EC - Electromagnetic compatibility directive
EDILKAMIN S.p.a. will decline all responsability of malfunctioning or damage to the equipment in case of unauthorized
substitution, assembly or modifi cations of any sort on the said equipment on the part of non-EDILKAMIN personnel.