EdilKamin PELLINSERT 54 Instalación Uso Y Mantenimiento página 24

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
EASY INSTALLATION KIT FOR A FIREPLACE WITH AN ALREADY
INSTALLED COVERING
fig. 1
1st step (Figs. 1-2)
- Enter a steel flue into the old masonry chimney flue and
apply the smoke channel supplied (A) to its base, so as to con-
nect it to the Pellinsert smoke outlet (this will be misaligned).
- Install the support plate (B), which will have an insert, and
fasten it into its definite position with dowels.
- Position the centring bracket (C) of the smoke channel (A)
and fasten it with the bolts supplied.
- Fit the smoke channel onto the collar (D) of the bracket (C)
by resting it onto the screw (* fig 2).
E
E1
fig. 2
OPENING FRAMEOPENING FRAME
Pellinsert is equipped with an opening frame. When replacing Edilkamin Firebox series 54, profile (X) that extends over
the lower border, must be removed (Fig. 6). This profile can be easily removed by using a screwdriver to lever it after
having removed the screws at both corners.
X
lower profile to be removed
fig. 6
N.B.: INSTALLATIONS WITH NEW COVERINGS MUST BE SET UP IN ACCORDANCE WITH
THE ABOVE MENTIONED RECOMMENDATIONS
(consisting of plate B and bracket C)
A
C
B
D
*
fig. 4
It is absolutely necessary to leave enough space along the
perimeter of the insert for air circulation in order to prevent
this from overheating (refer to the area highlighted with a
pink background on the section and on the plan found on the
following page). Moreover, two grilles must be installed so as
to enhance air circulation: one at the bottom of the covering
(A) and the other on the upper part of the mantel (B) - refer to
the following page. It must be possible to remove Pellinsert
for "possible" inspections after being installed, even if the
fireplace is covered.
24
mat
G
steel rod
fig. 3
2nd step (Fig. 3)
- Wrap the flue or smoke channel with a mat, (G) made of a
number of ceramic fibre layers or equivalent material, which
is thick enough to fill the gaps formed between the new steel
flue and that made of masonry.
- Place the inert into the centre of the support plate (B) and
push it until it reaches the end-of-travel.
3° fase (fig. 4-5)
- Remove the support screw (*) and fit the smoke channel onto
the smoke outlet (F), blocking it in place with the screw (°) .
- This is implemented through the opening (E) at the top of the
insert, after having removed the plate (E1) fastened with 2
screws (refer to Fig. 2).
°
F
fig. 5
®
E
B
A
*
E

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido