EdilKamin PELLINSERT 54 Instalación Uso Y Mantenimiento página 25

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
N.B.: IMPORTANT FOR INSTALLATION CONDITIONS
5 cm
External
intake
connection
Ø 10 cm
NOTES ON FITTING THE COVERING
In order to define the exact position of the Pellinsert 54, it is important to check which covering will be used to complete it.
Positioning differs according to the model chosen (see assembly instructions given in the packaging of each covering).
Always check that installation is perfectly vertical and horizontal.
Coverings, counter-hoods and their ventilation
Before installing the covering, check that all connections, commands and moving parts are perfectly functional.
Check this with the insert on and working for a few hours. Do so prior to fitting the covering in order to intervene as
necessary.
Finishing works, such as construction of the counter-hood, covering assembly, pilaster preparation, painting, etc., should
be carried out once the final test has been passed.
Edilkamin will therefore not be held liable for any charges deriving from both demolition and reconstruction works, even
where consequent to replacement of any faulty insert parts.
Rather, at least 1 cm. (approx.) space must be left to allow air to flow, thereby preventing heat from accumulating.
The counter-hood can be created from fireproof plasterboard panels or plaster sheets. When creating this, the air
circulation grill must be included, as previously specified.
During the construction phase of the covering it is fundamental to ensure that the combu-
stion air is restored to prevent pressure phenomena in the room where the fireplace is instal-
led (refer to the Chapter regarding the external air inlet on page 22)
In addition to the above, always consider the indications given by paragraphs 4.4 and 4.7 of standard UNI 10683/2005
"insulation, finishes, coverings and safety recommendations".
Output for recirculation
B
of hot air within the
covering
Warm air outlet at
the front
inlet for recirculation
A
of air into the room
It is absolutely necessary to set up enough space along
the perimeter of the insert for air circulation to prevent
this from overheating (refer to the area highlighted with
a pink background on the section and on the plan).
Moreover, two grilles must be installed in order to
enhance air circulation: one at the bottom of the cove-
ring (A) and the other on the upper part of the mantel
(B).
External intake connection Ø 10 cm
5 cm
5 cm
SECTION
25
5 cm
SYSTEM

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido