Please unfold page 3. Then you can always see the operating ele-
GB
ments de scribed.
1 Operating Elements and Connections
1 HOLD indication; when freezing a reading or when measuring the
average value
2 Indication of operating mode
Auto: automatic selection of the measuring range
Man.: manual selection of the measuring range
3 Indication of the present measuring range
4 Power switch
5 Indication of the impedance value measured
6 Indication of the corresponding power consumption at a 100 V
system
7 Button RANGE for manual range selection or for activating the
automatic range selection
8 Button HOLD with two functions:
automatic range selection: for freezing a measured value
manual range selection: for starting a measurement of the average
impedance value in a noisy environment
9 4 mm jacks for connecting the test leads
10