Obstacle Detection Functioning; Declaration Of Conformity - Erreka VIVO-D102 Manual Del Instalador

Quadro de manobra para o accionador "izar" com encoder
Ocultar thumbs Ver también para VIVO-D102:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

DESCRIPTION OF THE PRODUCT
4

OBSTACLE DETECTION FUNCTIONING

The door can detect an obstacle in two ways:
A- Detection by photocell or safety strip in closing (SG.C)
During opening
If, during opening, the closing safety device (SG.C) is
activated, the door continues to open.
B- Direct detection (built-in safety)
During opening
If, during opening, the door collides with an obstacle, it
inverts direction and slightly closes. The door remains
on standby until a key command is received. When the
key command is received, it closes completely.
5

DECLARATION OF CONFORMITY

Erreka Automatismos declares that the VIVO-D102/
VIVO-D102M electromechanical operator has been
designed for use in a machine or for assembly along
with other elements in order to form a machine in line
with Directive 2006/42/EC.
The VIVO-D102/ VIVO-D102M control boards allow
installations which fulfil Standards EN 13241-1 and
EN 12453, provided they are installed appropriately and
correctly. The installer shall be responsible for proper
installation.
42
Installation Manual
During closing
If the closing safety device (SG.C) is activated during
closing, the door inverts operation direction and opens
completely.
During closing
If, during closing, the door collides with an obstacle, it
inverts operation direction and opens completely.
VIVO-D102/ VIVO-D102M control boards comply with
safety legislation, in line with the following directives
and regulations:
• 2006/95/CE (low voltage materials)
• 2004/108/EC (electromagnetic compatibility)
• EN 60555-2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Vivo-d102m

Tabla de contenido