Functioning Modes; Obstacle Detection Functioning; Declaration Of Conformity - Erreka VIVO-M201 Manual Del Instalador

Cuadro de maniobra universal con paro suave para motores monofásicos
Ocultar thumbs Ver también para VIVO-M201:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3

FUNCTIONING MODES

Automatic mode (DIP4 = ON)
Opening: this begins by activating the key device
(transmitter, magnetic key, key switch, etc).
• Step-by-step opening (DIP3=ON): if, during the
opening process, the key device is activated, the two
leaves of the gate come to a stop. The gate closes if
activated again.
• Community
opening
opening, the control board does not obey the key
commands.
Step-by-step mode (DIP4 = ON)
Opening: this begins by activating the key device
(transmitter, magnetic key, key switch, etc).
• Step-by-step opening (DIP3=ON): if, during the
opening process, the key device is activated, the two
leaves of the gate come to a stop. The gate closes if
activated again.
• Community
opening
opening, the control board does not obey the key
commands.
4

OBSTACLE DETECTION FUNCTIONING

Detection by safety device (photocell or mechanical strip)
Interior device (S.INT)
During opening: if, during the opening process, the
interior device detects an obstacle, the gate comes to a
stop. Once the obstacle disappears, the gate opens
completely after a few moments.
During closing: if, during the closing process, the
interior device is activated, the gate comes to a stop.
Once the obstacle disappears, the gate opens
completely after a few moments.
5

DECLARATION OF CONFORMITY

Erreka Automatismos declares that the VIVO-M201(M)
control boards have been designed for use in a machine
or for assembly along with other elements in order to
form a machine in line with Directive 2006/42/EC.
VIVO-M201(M) control boards allow the carrying out of
installations in line with Standards EN 13241-1 and
EN 12453.
(in pedestrian and total operation)
(DIP3=OFF):
during
(in pedestrian and total operation)
(DIP3=OFF):
during
DESCRIPTION OF THE PRODUCT
S t a n d b y : t h e g a t e r e m a i n s o p e n d u r i n g t h e
programmed time.
• If, during standby, the safety device is activated,
standby time starts again.
• DIP6=OFF: if, during standby, the key device is
activated, standby time starts again.
• DIP6=ON (automatic mode optional): if, during
standby, the key device is activated, the gate begins
to close.
Closing: at the end of standby time (or when using the
key device if DIP6=ON), the closing operation begins.
If the key device is activated during closing, the gate
reverses operation direction and opens completely.
Standby: the gate remains open until a key command
is received.
Closing: closing starts by running the key device.
If the key device is activated during closing, the gate
reverses operation direction and opens completely.
Exterior device (S.EXT)
During opening: the gate continues to open even
when the exterior device detects an obstacle.
During closing: if, during the closing process, the
exterior device is activated, the gate comes to a stop
and begins to open immediately.
VIVO-M201(M) control boards comply with safety
legislation, in line with the following directives and
standards:
• 2006/95/CE (low voltage materials)
• 2004/108/EC (electromagnetic compatibility)
• EN 60555-2
• UNE-EN 60335-1
Control board VIVO-M201(M)
41