Set logic alarm level to LOW (alarm when input tensionless)
Password
Command
Example
Result
Set logic alarm level to switching (alarm when input tension changes)
Password
Command
Example
Result
Request logic alarm level
Password
Command
Example
Result
Inhibition time input 1
Password
Command
Example
Result
Inhibition time input 2
Password
Command
Example
Result
Request inhibition times
Password
Command
Example
Result
Reset inhibition time input 1
Password
Command
Example
Result
V. 02 – 15/05/2012
HAMGSM133
LIVx:B
x = 1 (input 1) or 2 (input 2)
LIV1:B
Set alarm level on input 1 to low, alarm is activated when input 1 loses
tension.
LIVx:V
x = 1 (input 1) or 2 (input 2)
LIV1:V
When tension changes on input 1, e.g. from low to high, the alarm is
activated.
LIV?
LIV?
Get a list of logic alarm levels on both inputs.
INI1:mm
mm = time in minutes (00~59)
INI1:02
After alarm activation, the device will not check the alarm level on input 1 for
2 minutes (inhibition time). Default = 5 minutes
INI2:mm
mm = time in minutes (00~59)
INI2:15
After alarm activation, the device will not check the alarm level on input 2 for
15 minutes (inhibition time). Default = 5 minutes
INI?
INI?
Get a list of the inhibition time on both inputs.
TIZ1x
x = 0 (no reset) or 1 (reset)
TIZ11
Inhibition time reset on input 1 when input 1 is idle. Default = no reset
10
©Velleman nv