8.4
With a PC and USB interface
Refer to the illustrations on pages 3, 4 and 5 of this manual.
This mode allows setting up HAMGSM133 with a computer and software (English) you can download from the
Velleman website connected through a USB interface (not included, order ID HAMGSM133/USB).
Install the software on the PC before connecting the HAMGSM133 to the USB port.
With the software, you can manage all programming and settings as well as change the list of enabled users.
This speeds up the initial setup and saves on the cost of SMS.
After starting the software, make sure the communication speed is set to 9600 Baud (8, N, 1).
Refer to the full user manual for more information on the installation and use of the software.
Note: While the device is connected to a PC, managing via SMS is disabled.
Installing the software
•
Go to
www.velleman.be
•
On the product page, click Software and then Save.
•
Run the setup file and follow the instructions on the screen.
•
When installation is completed, start the software. The configuration window [A] appears.
•
Connect the HAMGSM133 to the USB port of the computer using an appropriate cable (not included).
•
Select the desired COM port (top left).
•
Click on 'Connect' (top centre) to activate the connection. When data is already present inside the
module, it will be shown.
•
If no master number is available in the module, the "Waiting for Call for Master Number Storage"
message appears in the log window [B] (at the bottom of the screen). Make a call to the HAMGSM133
before proceeding. A confirmation message is shown in the log window.
•
The configuration window now shows a number of tabs.
•
In the "Info" tab [C] you can find model number, firmware version and IMEI (International Mobile
Equipment Identity). It is also possible to change the password in this tab.
To be able to change the settings, enter the current password into the "system password" field and click
"Save".
If the device does not react to commands from the computer, make sure the password stored in the PC
is the same as the one specified in the management program.
•
The "Phone Number" tab [D] is used to manage phone numbers. Store or delete numbers, or request a
full list (shown on the right). The overview window has two tabs, one for "Master Numbers" [D] and
another for "Gate Control Numbers" [E].
Each action must be confirmed.
•
Use the tab "Notice" [F] to enable or disable numbers on specific positions in the list. Enable to let them
receive SMS or alarm calls.
•
Configure the activation logic (high/low/switch-over) of the two inputs in the tab "Inputs" [G].
Check the "Request timing" checkbox and click "Run" to see the current settings in a pop-up window
[H].
•
The "Outputs" tab [I] is used to control the relays manually.
•
In every window it is possible to see an extended log showing all communication that goes through the
communication port. Click on "Enable extended LOG" at the bottom of the screen. The extended log
window pops up [J].
V. 02 – 15/05/2012
HAMGSM133
and search for the product ID HAMGSM133/USB.
14
©Velleman nv