MAIN COMPONENTS
1 Front panel
2 Horizontal air discharge blades
3 Vertical air discharge blades
4 Air filter
5 Heat exchanger coil
1
4
DESCRIPTION OF COMPONENTS
FRONT PANEL
The air intake is via the slots. Lifting
the panel gives access to the air filter
and the internal parts
RECEIVER
Infra red signal receiver for versions
with microprocessor controller
DISPLAY
The display is mounted on the front
panel, only for versions with
microprocessor controller. It shows
the fan speed, operating mode,
temperature, error messages, and
timer
AIR FILTER
Washable air filter that can easily be
removed
HEAT EXCHANGER COIL
Made of copper tubes with turbo
lanced aluminium fins
DISCHARGE AIR
The horizontal blades are:
- motorised for versions fitted with
microprocessor controller.
- manual for versions not fitted with
microprocessor controller
The vertical blades are manually
adjustable to allow optimal air dis-
charge
AUXILIARY EMERGENCY SWITCH
The auxiliary emergency switch, only
for versions with microprocessor con-
troller, allow the fan coil unit to be
turned on or off if the wired control
panel or remote control are not oper-
FCW
2
3
5
ating
FAN ASSEMBLY
The fan assembly consists of an
extremely compact and quiet tangen-
tial type fan.
2-WAY WATER VALVE
The FCW_2V fan coil unit is supplied
as standard with a 2-way on/off water
valve and electro-thermal actuator
controlled by the fan coil controller ,
based on the water temperature and
the temperature of the room
3-WAY WATER VALVE
The FCW_3V fan coil unit is supplied
as standard with a 2-way on/off water
valve and electro-thermal actuator
controlled by the fan coil controller ,
based on the water temperature and
the temperature of the room
TLW2 REMOTE CONTROL (FCW
a c c e s s o r y f o r v e r s i o n s w i t h
microprocessor controller)
Accessory essential for the fan coil
unit operation, as an alternative to
the PFW2 wired control panel.
The TLW2 remote control is provided
loose from the fan coil unit.
remote control can control several
fan coil units.
The remote control makes it possible to
set all the operating parameters of the
unit. These parameters are shown on
a liquid crystal display making pro-
gramming operations easier.
The remote control is supplied with a
bracket allowing it to be hung on the
wall.
6 Auxiliary emergency switch
7 Electric terminal connections
8 Front case
9 Frame
10 Display
10
3
6
7
TLW2
PFW2
PFW2 WIRED CONTROL PANEL
(FCW accessory for versions with
microprocessor controller)
Accessory essential for the fan coil
unit operation, as alternative to the
TLW2 remote control.
The wired control panel must be
installed on the wall and connected
to the fan coil unit with the cable
provided loose.
The panel cable is 4 metres long.
The PFW2 makes it possible to set the
main operating parameters of the
unit. These parameters are shown on
a liquid crystal display making pro-
gramming operations easier.
A PFW2 wired control panel can con-
trol just one fan coil unit.
One
IFCW3LJ 1207 - 5375700_00
9
8
33