Electrical Connections - GE PP989 Manual Del Propietario E Instrucciones De Instalación

Ocultar thumbs Ver también para PP989:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

BefoRe mAkING eleCTRICAl
17
CoNNeCTIoNs
Note to electrician: The power leads supplied with this
appliance are UL-recognized for connection to large
gauge household wiring .
The insulation of these leads is rated at temperatures
much higher than the temperature rating of household
wiring . The current carrying capacity of a conductor is
governed by the wire gauge and also the temperature
rating of the insulation around the wire .
Aluminum Wiring –
ImPRoPeR CoNNeCTIoN of AlumINum house
WIRING To The CoPPeR leADs CAN ResulT IN
seRIous PRoBlems.
Attach copper wires to aluminum wiring using special
connectors designed and UL-listed for joining copper
to aluminum . Follow the connector manufacturer's
recommended procedure closely .
service loop – Leave a loop in the wires to the cooktop
so that the cooktop can be lifted 12 inches without
having to disconnect the wiring .
eleCTRICAl RequIRemeNTs*
model #
Voltage
PP989
120/240V
120/208V
* For reference only . Verify with product rating plate .
Electrical installation kit JXCk89 may be ordered
separately and includes all the parts necessary to
connect the cooktop to typical rough-in wiring .
Installation Instructions
eleCTRICAl CoNNeCTIoNs
WARNING:
frequency
kW
60Hz
9 . 1 KW
60Hz
6 . 9 KW
Rating Plate
INsTAll 3/4" fleXIBle CoNDuIT
18
Remove the screws holding
the wire compartment cover
and remove the cover .
Feed the power
supply leads
through the
conduit; be sure to
leave enough length
to properly connect
these leads to the
cooktop power leads .
Thread the leads
through an anti-
short bushing and
firmly seat the
bushing in the end
of the conduit .
Feed the leads
through the hole
in the wire
compartment .
As local codes
permit purchase
a listed conduit
connector suitable
for the size conduit .
Insert the conduit
through the
connector and
attach it to the
cover . Allow
enough slack to
easily attach the
wires to the
cooktop .
Note: Do not install
the cooktop without
a listed conduit
connector . The
conduit connector
should be installed
before reinstalling
the wiring cover .
When complete,
reinstall the wire
compartment cover .
25
Power Supply
Anti-Short
Conduit
Leads
Bushing
Bushing (Fully Seated)
Conduit
Connector
Conduit
Cover

Publicidad