Dimmer Curves; Dmx Mode - Cameo ZENIT P 40 Manual De Usuario

Tabla de contenido

Publicidad

You will then be taken to the sub-menu to set the following sub-menu items:
Settings
Display Reverse
=
Flip Display
Display Backlight
=
Display lighting
DMX Fail
=
Operation status with DMX
signal interruption
Dimmer Curve
=
Dimmer Curve
Dimmer Response
=
Dimmer response
Color Calibration
=
Colour calibration
Autolock
=
automatic locking of the
control elements
IR Remote
=
enable / disable operation via
IR remote control
Factory Reset
=
Reset to factory setting
Confirm all inputs with ENTER.

DIMMER CURVES

linear
exponential
DMX value
SYSTEM INFORMATION (System Info)
Pressing MODE will take you to the selection menu for system settings (--- Menu ---). Using UP and DOWN, select the menu item "System Info"
(observe the arrow) and confirm with ENTER.
---------------- Menu ----------------
DMX Address

DMX Mode

Stand Alone
Slave
Settings
System Info
The required sub-menu can be selected as desired by using UP and DOWN in order to show the corresponding information by pressing ENTER.
System Info
Firmware
=
Displays the Firmware version
Temperature
=
Temperature display of the LED unit
Operation Hours
=
Operating time display
logarithmic
DMX value
DMX value
On
= Rotation of the display by 180° (e.g. overhead installation)
Off
= no rotation of the display
On
= permanently on
Off
= deactivation after approx. 1 minute of inactivity
Hold
= last command is held
Blackout
= activates Blackout
Linear
= The light intensity increases linearly with the DMX value
Exponential
= Adjustment of the light intensity is finer in the lower DMX value
range and coarser in the upper DMX value range
Logarithmic
= Adjustment of the light intensity is coarser in the lower DMX value
range and finer in the upper DMX value range
S-Curve
= Adjustment of the light intensity is finer in the lower and upper
DMX value ranges and coarser in the middle DMX value range
Led
= The spotlight responds abruptly to changes in the DMX value
Halogen
= The spot behaves in a manner similar to that of a halogen lamp
with gentle changes in brightness
Red, Green,
= individual colour calibration. Cross-operating mode brightness
Blue, White
setting of 4 RGBW LED groups with values ranging from 000 to 255.
On
= automatic locking of the control elements after 1 minute of
inactivity. Display shows: "Locked!"
Unlock: simultaneously press UP and DOWN for about 5 seconds
Off
= automatic locking of the control elements is deactivated
On
= functionality enabled
Off
= functionality disabled
Reset to factory settings: ENTER -> "Reset Now! -> ENTER
S-curve
DMX value
Main CPU
Vx.x
LED
xx°C / xx°F
Unit
°C (= display in degrees Celsius)
°F (= display in degrees Fahrenheit)
xx:xxh
Displays the operating time in hours and minutes
19