Product Specifications; Generator Specifications; Engine Specifications; Know The Generator - Generac XT8000E Serie Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

• Ignition System
— Spark Plug
— Ignition Module
• Exhaust System
— Exhaust Manifold
— Muffler
— Pulsed Air Valve
— Catalyst
2.4 — P
S
RODUCT
2.4.1 — Generator Specifications
Rated Power ........................................................... 8 kW
Surge Power .........................................................10 kW
Rated AC Voltage............................................... 120/240
Rated AC Load
Current @ 240V ........................................ 33.3 Amps**
Current @ 120V ........................................ 66.6 Amps**
Rated Frequency ............................. 60 Hz @3600 RPM
Phase .........................................................Single Phase
Operating Temperature Range ... 0° F (-17° C) to 110° F
(43° C)*
* Operating temperature range: 0° F (-18° C) to 104° F (40° C). When
operated above 77° F (25° C) there may be a decrease in power.
** Maximum wattage and current are subject to, and limited by, such
factors as fuel Btu content, ambient temperature, altitude, engine
condition, etc.. Maximum power decreases about 3.5% for each
1,000 feet above sea level; and will also decrease about 1% for each
10° F (-12.2° C) above 60° F (16° C) ambient temperature.
2.4.2 — Engine Specifications
Displacement ........................................................ 420 cc
Spark Plug Type ................................... Champion N9YC
Spark Plug Gap ....... 0.028-0.031 inch or (0.70-0.80 mm)
Fuel Capacity ................................7.5 gallons/ 28.4 liters
Oil Type ................................................see Section 2.6.1
Oil Capacity..................................1.06 Quarts (1.0 liters)
Run Time at 50% Load ..................................... 11 Hours
XT8000E Series Portable Generator
PECIFICATIONS
1
Figure 2-5. Control Panel
2.5 — K
NOW
Compare the generator to Figures 2-5 through 2-7 to
become familiarized with the locations of various controls
and adjustments.
Read the Owner's Manual and Safety Rules before
operating this generator.
1. 120/240 Volt AC, 30 Amp, Locking Receptacle –
Supplies electrical power for the operation of 120
and/or 240 Volt AC, 30 Amp, single-phase, 60 Hz
electrical lighting, appliance, tool and motor loads.
2. Hourmeter - Tracks hours of operation to perform
required maintenance.
3. Circuit Breakers (AC) – A 2-pole circuit breaker pro-
tects the rated output of the 30 Amp Twistlock outlet.
Each duplex receptacle is provided with a push-to-
reset circuit breaker to protect against electrical over-
load.
4. 120 Volt AC, 20 Amp GFCI Duplex Outlets – Sup-
plies electrical power for the operation of 120 Volt
AC, 20 Amp, single-phase, 60 Hz, electrical lighting,
appliance, tool and motor loads. It also provides pro-
tection with an integral Ground Fault Circuit Inter-
rupter, complete with a press to "Test" and "Reset"
button.
5. Off/Run/Start Switch – Controls the operation of the
generator.
6. Battery Charger Input – Permits recharging of the
battery. A 12 volt charger is included. A 1.50 Amp in-
line fuse is located behind the control panel to protect
the battery when charging.
7. Powerbar – Indicates the amount of power being
used from the generator. Each section is approxi-
mately 20%.
8. Idle Control Switch – operates the engine at normal
(high) rpm when there is an electrical load present
and automatically reduces the engine to a lower rpm
when a load is not present. The system can also be
turned off to operate the engine at a higher rpm at all
times.
2
4
3
T
G
HE
ENERATOR
7
8
5
6
7