Warnings/Input Limits; General Specifications - Southwire 15190T MaintenancePRO Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Input Limits
Function
Voltage AC/DC
µA/mA Current AC or DC
10A Current AC or DC
Frequency, Resistance,
Capacitance, Diode Test,
Continuity
Temperature
General Specifications
Insulation
Class 2, Double insulation
Diode Test
Test current of 0.9mA maximum, open circuit voltage 3.2V DC typical
Audible signal will sound if the resistance is less than 30Ω (approx.)
Continuity Test
test current <0.35mA
PEAK
Captures peaks >1ms
Low Battery Indication
Battery indicator will flash
Display
TFT LCD color display
Polarity
Automatic (-) negative polarity indication
Overrange Indication
"OL" is displayed
Measurement Rate
20 times per second, nominal
Auto Power Off
5 to 30 minutes (approx.) with disable
Input Impedance
>10MΩ VDC & >9MΩ VAC
AC Response
TrueRMS
ACV Bandwidth
50Hz to 20kHz
Operating Temperature
41°F to 104°F (5°C to 40°C)
Storage Temperature
-4°F to 140°F (-20°C to 60°C)
Operating Humidity
Max 80% up to 87°F (31°C) decreasing linearly to 50% at 104°F (40°C)
Storage Humidity
<80%
Operating Altitude
7000ft. (2000 meters) maximum
Battery
One 7.4 volt rechargeable Lithium Ion battery
Fuses
mA, µA ranges: 800mA/1000V ceramic fast blow
10A range: 10A/1000V ceramic fast blow
Dimensions/Weight
6.6" x 3.1" x 2" (168 x 79 x 51mm)/0.90lb (408g)
Safety
Complies with UL 61010-1 3rd edition for measurement CAT IV 600V,
CAT lll 1000V, Pollution Degree 2
Maximum Input 15190T
1000VAC rms, 1000VDC
800mA 1000V fast acting fuse
10A 1000V fast acting fuse
(10A for 30 seconds max. every 15 minutes)
1000VAC rms, 1000VDC
1000VAC rms, 1000VDC
3
International Safety Symbols
Potential danger. Indicates the user must refer to the manual for important safety information
Indicates hazardous voltages may be present
Equipment is protected by double or reinforced insulation
MAX
Indicates the terminal(s) so marked must not be connected to a circuit where the
1000V
voltage with respect to earth ground exceeds the maximum safety rating of the meter
Indicates the terminal(s) so marked may be subjected to hazardous voltages
Category Rating
Brief Description
Typical Applications
Single phase
- Household appliances, power tools
CAT II
receptacles and
- Outlets more than 30ft (10m) from a CAT III source
connected loads
- Outlets more than 60ft (20m) from a CAT IV source
Three phase circuits
- Equipment in fixed installations such as 3-phase motors, switchgear and distribution panels
CAT III
and single phase
- Lighting circuits in commercial buildings
lighting circuits in
- Feeder lines in industrial plants
commercial buildings
- Any device or branch circuit that is close to a CAT III source
Connection point to
- Primary distribution panels
CAT IV
utility power and
- Overhead or underground lines to detached buildings
outdoor conductors
- Incoming service entrance from utility
- Outdoor pumps
The measurement category (CAT) rating and voltage rating is determined by a combination of the meter, test probes and any
accessories connected to the meter and test probes. The combination rating is the LOWEST of any individual component.
FCC Statement
Warning: Changes or modifications to this unit not expressly approved by the Southwire Company, LLC. could void the user's authority
to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
The device must not be co-located or operating in conjunction with any other antenna or transmitter.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
IC Statement
This device complies with RSS247 of Industry Canada. This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of the device.
Radiation Exposure Statement: The product comply with the Canada portable RF exposure limit set
forth for an uncontrolled environment and are safe for intended operation as described in this manual.
The further RF exposure reduction can be achieved if the product can be kept as far as possible from
the user body or set the device to lower output power if such function is available.
Complies with
IDA Standards
DA107392