Accessing Battery And Changing Fuse; Specifications - Southwire 15190T MaintenancePRO Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Accessing Battery and Changing Fuse

WARNING:
To avoid electric shock, remove test leads from the meter before removing
the battery door. ONLY use an exact replacement UL rated fuse when replacing fuses.
1. Lift up tilt stand to access battery door.
2. Use small coin to unlock battery door.
3. Lift up on tab below lock to remove battery door.
4. Lift up on battery to remove.
5. Use an exact replacement when replacing
battery.
6. When replacing fuse, remove the old fuse by
gently pulling it out from its holder.
7. Install new fuse into holder.
8. Always use an exact replacement UL rated fuse of the proper size and value.
800mA/1000V (6.3 x 32mm) fast blow for the µA and mA ranges.
and 10A/1000V (10 x 38mm) fast blow for the 10A range.
NOTE: 800mA fuse can be accessed by carefully removing rubber cover. Reinsert cover after replacing
fuse.
WARNING:
To avoid electric shock, do not operate meter until the battery door is in place and
fastened securely.
WARNING:
When replacing battery, follow local waste management regulations for disposal
of old battery.
LOCKED
UNLOCKED
Cover
Tilt Stand
Battery
Fuse
29
Specifications
15190T Specifications
Function
Range
Resolution
AC Voltage
500.00mV
0.01mV
5.0000V
0.1mV
50.000V
1mV
500.00V
10mV
1000.0V
0.1V
Input Protection: 1000V AC rms or 1000V DC
Function
Range
Resolution
DC Voltage
500.00mV
0.01mV
5.0000V
0.1mV
50.000V
1mV
500.00V
10mV
1000.0V
0.1V
Input Protection: 1000V AC rms or 1000V DC
Function
Range
Resolution
AC + DC
5.0000V
0.1mV
Voltage
50.000V
1mV
500.00V
10mV
1000.0V
0.1V
Input Protection: 1000V AC rms or 1000V DC
Function
Range
Resolution
AC Current
500.00µA
0.01µA
5000.0µA
0.1µA
50.000mA
1µA
500.00mA
10µA
10.000A
1mA
Overload Protection: 800mA /100V and 10A/1000V Fuses
AC current ranges are specified from 5% to 100% of range
Function
Range
Resolution
DC Current
500.00µA
0.01µA
5000.0µA
0.1µA
50.000mA
1µA
500.00mA
10µA
10.000A
1mA
Overload Protection: 800mA/1000V and 10A/1000V Fuses
Accuracy ±(% of reading + digits)
50/60Hz
<1kHz
<5kHz
±(1.0% + 5)
±(3.0% + 5)
±(0.5% +5)
±(3.5% + 10)
±(1.5% + 10)
unspecified
AC voltage ranges are specified from 5% to 100% of range
Accuracy ±(% of reading + digits)
±(0.1% + 5)
±(0.5% + 5)
±(0.1% + 5)
Accuracy ±(% of reading + digits)
<1kHz
<5kHz
±(1.2% + 20)
±(3.00% + 20)
Accuracy ±(% of reading + digits)
<1kHz
<5kHz
± (0.8% + 5)
± (3% + 5)
Accuracy ±(% of reading + digits)
±(0.2% + 5)
±(0.3% + 8)
±(0.5% + 8)
30
< 20kHz (1)
±(5.5% + 20
unspecified
unspecified

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido