10.5.6
TURNING OFF THE STOVE
In order to turn off the stove, press button no.4 during a few seconds.
Once it has been turned off, it will start the final cleaning stage, in
which the pellet supply stops and the smoke extractor will be working
to the maximum speed. This stage would not finish until the stove has
reached the appropriate cooling temperature (see drawing D67).
10.5.7
STOVE TURNED OFF
When the stove is turned off, the display shows the following
information (see drawing D68):
10.5.8
RE-IGNITION OF THE STOVE
When the stove is turned off it would not be possible to restart it
up until some safety time goes by and the stove is cold enough. If
you try to start-up the stove, the display will show up the following
information (see drawing D69):
10.5.9
DISPLAY BLOCK
The display of your stove can be locked to prevent accidental
pressing of any of the keys. To do so, it is necessary to make a short
press on the button number 3 and then on button 4 (it is not pressing
both buttons simultaneously). Thus, it will be displayed the following
message (see drawing D70):
To unlock it, proceed likewise; make a short press on the button
number 3 and then on button 4 (it is not pressing both buttons
simultaneously). Thus, it will be displayed the following message
(see drawing D71):
11 ALARMS
In case of an anomaly during the operation, the electronics of the
stove intervene and highlight the irregularities that have ocurred in
the different working phases, depending on the type of fault.
Every alarm situation blocks the stove. By pressing button 4 we can
unblock it. Once the stove has reached the appropriate cooling
temperature, the user can restart it up.
11.1
POWER SUPPLY FAILURE (BLACK OUT)
In the event that power supply is cut for less than 30 seconds, the
stove will restart and continue with its normal working state.
In the event that power supply is cut for greater than 30 seconds,
when power is restored, the stove, as a safety measure, goes
straight to the Final Cleaning stage until the stove temperature
reaches the appropriate cooling temperature.Once the final cleaning
has finished, the stove will turn off until the user ignite it again (see
drawing D72).
11.2
SMOKE TEMPERATURE PROBE ALARM
This alarm goes off when the probe in charge of detecting the
exhaust stack temperature is disconnected or it breaks. During the
alarm status, the stove will be in the turn-off stage (see drawing
D73).
11.3
SMOKE TEMPERATURE EXCESS ALARM
It goes off when the probe detects a smoke temperature higher than
270°C. Therefore the display shows the following message (see
drawing D74):
During the alarm state, the stove will be in the turn-off stage.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
21:10
23 ºC
FINAL
CLEANING
21:10
22 ºC
OFF
STAND-BY
COOLING
KEYS
FROZEN
KEYS
FREE
12:42
22 ºC
FINAL
CLEANING
ALARM 2
SMOKE
SENSOR
ALARM 3
ALARM
SMOKE TEMP.
40
P-3
D67
P-1
D68
D69
D70
D71
P-3
D72
D73
D74
AIR SERIES