10.4.10
MENU 9. FAN MODE
This menu is only available for model Abril-Ex. For all other models, Menu 9 "technical adjustment" is reserved for technical personnel with
specific experience in the product and with a password.
This menu allows you to select the activation or deactivation of the main tangential turbine of hot air (fan 1). You can choose between the
option of forced ventilation (turbine activated) or natural ventilation (turbine deactivated). In order to access to this menu, it is necessary to
confirm with the key number 3 "SET" and then with the keys 1 and 2, select the option chosen (see drawings D59 and D60 ).
Menu 09
FAN MODE
Natural
WARNING!!!
In the Abril model, if you want to deactivate the running of the main turbine, depending on the working power of the stove,
the type of fuel used and the parameterization of the stove that the installer has made, it is probable that the temperature
of the smoke exceeds 240ºC and the stove enters in modulation process for this reason. In this case, it is recommended to
check the parameterization of the stove or reduce the power.
10.5
USER MODE
Below is a description of the display normal operation according to
the available functions.
Before the ignition of the stove, the display shows the following
screen (see drawing D61): It is showed up the "off" state, the room
temperature, the established working power and the current hour.
10.5.1
IGNITION OF THE STOVE
In order to ignite the stove, press button no.4 during a few seconds.
The display will show the ignition state as follows (see drawing
D62):
The maximum length of the ignition phase is 20 minutes. After this
time, if there is no visible flame, the stove will automatically go into
the alarm state and the display will show the message "Ignition
Failure."
10.5.2
STOVE IN OPERATION
The hot air fan will start when the smoke temperature reaches a
minimum. Channeling fans will start only if enabled.
In this moment, the display will show the message "Work." After this,
our stove will be working normally (see drawing D63).
The display shows the ambient temperature in the room.
10.5.3
CHANGE OF THE SET-POINT ROOM
TEMPERATURE
In order to modify the setting room temperature, please press button
1 and 2 to increase or decrease it respectively (see drawing D64).
10.5.4
ROOM TEMPERATURE REACHES TEMPERATURE
FIXED BY THE USER
When the ambient temperature (of the room) reaches the value set
by the user or the smoke temperature reaches a too high value, the
stove will automatically operate at one lower power; it means that
modulates in power. See drawing D65.
Remember that if it is activated "stand-by mode", when the ambient temperature reaches the value set by the user plus a differential (2ºC) the
stove will be automatically turned off and will be on hold until the ambient temperature falls to the set temperature minus a differential (2ºC).
After that, the stove restarts automatically.
10.5.5
BURNER CLEANING
While the stove is working normally, some automatic cleanings of
the burner take place in 30 minutes intervals. This process consists
of cleaning the rest of pellet remaining in the burner in order to
guarantee a proper working of the stove (see drawing D66) and it
takes 30 seconds.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
D59
39
Menu 09
FAN MODE
Convector
14:24
21 ºC
P-2
OFF
14:35
21 ºC
P-2
IGNITION
15:18
21 ºC
P-3
WORKING
24 ºC
SET TEMP
ROOM
16:40
27 ºC
P-2
WORKING
MODULATION
16:40
22 ºC
P-2
BURNER
CLEANING
D60
D61
D62
D63
D64
D65
D66
AIR SERIES