0---
10--
add. start
Add. 2ch
erase 64
language
autoset
Control unit
software version
stat
vers
OK
No total
- +
manoeuvres(in hundreds)
n. cycles
OK
- +
No radio control
devices memorised
n. remotes
OK
- +
List of last 30 errors
err
OK
0---
password
40
- VIRGO SMART BT A
ACCESS MENUS Fig. 2
INSTALLATION MANUAL
150-
1520
See PARAMETERS MENU
See LOGIC MENU
hidden butt
release
desired button
hidden butt
release
desired button
See RADIO MENU
Diagnostics
code
START E external start input activated
STRE
START I internal start input activated
STRI
OPEN input activated
OPEN
CLOSE input activated
CLS
PED pedestrian input activated
PED
TIMER input activated
TIME
STOP input activated
STOP
Activation of PHOT photocell input or, if configured
as verified photocell, Activation of the associated
PHOT
FAULT input
Activation of PHOT OP opening photocell input or,
if configured as active verified photocell only when
PHOP
opening, Activation of the associated FAULT input
Activation of PHOT CL closing photocell input or, if
configured as active verified photocell only when
PHCL
closing, Activation of the associated FAULT input
Activation of BAR safety edge input or, if configured
as verified safety edge, Activation of the associated
BAR
FAULT input
Activation of BAR safety edge input with ACTIVE reversal
ONLY WHILE OPENING, or, if configured as verified safety
baro
edge active only while opening, Activation of the asso-
ciated FAULT input
Activation of BAR safety edge input with ACTIVE reversal
ONLY WHILE CLOSING, or, if configured as verified safety
barc
edge active only while closing, Activation of the associated
FAULT input
bft . . .
The board is standing by to perform a complete open-
+/-
ing-closing cycle uninterrupted by intermediate stops
SET
in order to acquire the torque required for movement.
WARNING! Obstacle detection not active
0000
Photocell test failed
ER01
+/-
Safety edge test failed
ER02
Opening photocell test failed
ER03
00
Closing photocell test failed
ER04
+/-
8k2 safety edge test failed
er06
Opening safety edge test failed
ER07
01.33
Closing safety edge test failed
ER08
02.01
Board hardware test error
ER1x*
........
Encoder error
ER2x*
30.15
Reverse due to obstacle - Amperostop
ER3x*
+/-
Thermal cutout
ER4x*
Communication error with remote devices
ER5x*
ER70, ER71
Internal system supervision control error.
ER74, ER75
Consistency error of the control unit's parameters
ER72
(Logics and Parameters)
D-track parameter error
ER73
Error during limit switch adjustment
Ersw
Only for
Error in setting the SAFE inputs
ERf3
*X= 0, 1, .., 9, A, B, C, D, E, F
10--
150-
ok
DESCRIPTION
LUX BT E - LUX G BT
1520
*** Password entry.
Request with Protection Level
logic set to 1, 2, 3, 4
Scroll up
Scroll down
Confirm/Switch on display
Exit Menù
C
= SWC2 motor 2 closing limit
switch input activated
O
= SWO2 motor 2 opening limit
switch input activated
C
= SWC1 motor 1 closing limit
switch input activated
O
= SWO1 motor 1 opening limit
switch input activated
35. 4 0
Instantaneous force motor 2
Instantaneous force motor 1
NOTES
 
 
 
 
 
 
 
 
 
 
 
 
Check photocell connection and/or logic settings
Check safety edge connection and/or logic settings
Check photocell connection and/or parameter/logic setting
Check photocell connection and/or parameter/logic setting
Check safety edge connection and/or parameter/logic settings
Check safety edge connection and/or parameter/logic settings
Check safety edge connection and/or parameter/logic settings
- Check connections to motor
- Hardware problems with board (contact technical assistance)
- Motor power or encoder signal cables inverted/disconnected.
- Actuator movement is too slow or stopped with respect to programmed
operation.
Check fo r obstacles in path
Allow automated device to cool
Check connection with serial-connected accessory devices and/or
expansion boards
Try switching the board off and back on again. If the problem persists,
contact the technical assistance department.
Pressing OK the detected settings are confirmed. The board will keep on
working with the detected settings.
The board settings must be checked (Parameters and Logics)
Pressing OK, the board will keep on working with D-track as a default.
An autoset is required
- Repeat the limit switch adjustment procedure.
- Try moving the maximum limits of both the opening and closing limit
switches.
- Caution: the last centimetre of the piston's stroke, during either opening or
closing, cannot be used.
Check the setting of the SAFE inputs is correct
 