Parameter
min.
max.
0
50
DIST. D ECEL
P A R T I A L
10
99
OPENING
1
99
OP. F ORCE
1
99
CLS. F ORCE
15
99
OP SPEED
15
99
CL SPEED
SLOW SPEED
15
99
0
250
Maintenance
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces can be reduced by using deformable edges.
TABLE "B" - LOGIC MENU - (logic)
Logic
Definition
Motor type
otor type
(Set the type of motor
connected to the
board).
Automatic Closing
TCA
Time
FAST CLS.
Fast closing
STEP-BY-
Step-by-step
STEP MO-
movement
VEMNT
PRE-ALAR
Pre-alarm
HOLD-TO-
Deadman
RUN
Block pulses during
IBL OPEN
opening
INSTALLATION MANUAL
Default
Personal
Definition
Deceleration distance
15
[%]
99
Partial opening M1 [%]
Leaf force during
50
opening [%]
Leaf force during
50
closing [%]
99
Opening speed [%}
99
Closing speed [%]
25
Slow-down speed [%]
Programming number of
operations for maintenan-
0
ce threshold
[in hundreds]
Cross out
Default
setting
used
0
Motors not active
1
ELI 250 BT - Do not use
2
PHOBOS N BT - Do not use
3
IGEA BT - Do not use
4
LUX BT - Do not use
0
5
LUX G BT - Do not use
6
SUB BT - Do not use
7
KUSTOS BT A - PHOBOS BT A - Do not use
8
GIUNO ULTRA BT A 20 - GIUNO ULTRA BT A50 - Do not use
9
VIRGO SMART BT A - 5 wires
10
VIRGO SMART BT A - 3 wires
0
Logic not enabled
0
1
Switches automatic closing on
0
Logic not enabled
0
1
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
0
Inputs configured as Start E, Start I, Ped operate with 4-step logic.
Inputs configured as Start E, Start I, Ped operate with 3-step logic. Pulse during closing reverses move-
1
0
ment.
2
Inputs configured as Start E, Start I, Ped operate with 2-step logic. Movement reverses with each pulse.
0
The flashing light comes on at the same time as the motor(s) start.
0
1
The flashing light comes on approx. 3 seconds before the motor(s) start.
0
Pulse operation.
Deadman mode.
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
1
Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
0
Emergency Deadman mode. Usually pulse operation.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, the device is
switched to Deadman mode, which will stay active until the OPEN UP or CLOSE UP keys are released.
Input 61 is configured as OPEN UP.
2
Input 62 is configured as CLOSE UP.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during opening.
0
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during opening.
Deceleration distance (switch from running speed to slow-down
speed) for motor(s) both during opening and during closing, given as a
percentage of total travel. WARNING: Once the parameter has been
edited, a complete uninterrupted opening-closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
Partial opening distance as a percentage of total opening following activation
of PED pedestrian command.
Force exerted by leaf/leaves during opening. This is the percentage of force
delivered, beyond the force stored during the autoset cycle (and subsequently
updated), before an obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current
safety requirements are met with the set value (*). Install anti-
crush safety devices where necessary (**).
Force exerted by leaf/leaves during closing. This is the percentage of force
delivered, beyond the force stored during the autoset cycle (and subsequently
updated), before an obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current
safety requirements are met with the set value (*). Install anti-
crush safety devices where necessary (**).
Percentage of maximum speed that can be reached by motor(s) during
opening. WARNING: Once the parameter has been edited, a complete
uninterrupted opening-closing cycle is required. WARNING: when the
display reads "SET", obstacle detection is not active.
Percentage of maximum speed that can be reached by motor(s) during
closing. WARNING: Once the parameter has been edited, a complete
uninterrupted opening-closing cycle is required. WARNING: when the
display reads "SET", obstacle detection is not active.
Opening and closing speed of motor(s) during slow-down stage, given as a
percentage of maximum running speed. WARNING: Once the parameter has
been edited, a complete uninterrupted opening-closing cycle is required.
WARNING: When the display reads ""SET"", obstacle detection is not active.
Allows you to set a number of operations after which the need for mainte-
nance will be reported on the AUX output configured as Maintenance or
Flashing Light and Maintenance .
Optional extras
WARNING: safety devices are not enabled.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
Description
VIRGO SMART BT A