Safe operation
Pos: 87 /Pumpen/Schlammsauger/MIDI Floating Fountain LM/Sicherer Betrieb Midi Floating Fountain - Motorschutz @ 10\mod_1248701052109_121.doc @ 65776 @
The MIDI Floating Fountain LM with an AC 230 V power supply is controlled by a control box with integrated motor
(overload) protection. The Midi Floating Fountain LM with an AC 400 V power supply is protected by an integrated
motor (overload) protection switch. Operation is only permitted with these protection devices functioning.
Pos: 88 /Alle Produkte/Sicherheit/Sicherer Betrieb/SIC ERW Sich. Betrieb - Nur mit Düse @ 10\mod_1249036289981_121.doc @ 67610 @
− Only use the unit with the nozzle fitted.
Pos: 89 /Alle Produkte/Sicherheit/Sicherer Betrieb/SIC ERW Sich. Betrieb - Keine Personen im Wasser @ 10\mod_1248351236831_121.doc @ 65210 @
− Only operate the unit if no persons are in the water!
Pos: 90 /Alle Produkte/Sicherheit/Sicherer Betrieb/SIC BAS Sich. Betrieb @ 11\mod_1250507406044_121.doc @ 69397 @
− Never operate the unit if either the electrical cables or the housing are defective!
− Do not carry or pull the unit by its electrical cable.
− Route all cables such that damage is excluded and nobody can trip over them.
− Never open the unit housing or its attendant components, unless this is explicitly required in the operating
instructions.
− Only use original spare parts and accessories for the unit.
− Never carry out technical modifications to the unit.
− Only have repairs carried out by customer service points authorised by OASE.
Pos: 91 /Alle Produkte/Dummy_module/Abstand 6 pt @ 7\mod_1196627997106_0.doc @ 41651 @
Pos: 92 /Alle Produkte/Überschriften/H1 Montage @ 7\mod_1202907725390_121.doc @ 43908 @
Installation
Pos: 93 /Alle Produkte/Dummy_module/Abstand 3pt @ 11\mod_1251901846864_0.doc @ 72826 @
Pos: 94 /Alle Produkte/"Achtung"-Texte/E-ACHTUNG - Gerät spannungsfrei schalten @ 10\mod_1249889357830_121.doc @ 68523 @
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures: Isolate the unit prior to reaching into the water and carrying out any work on the
unit. Secure the unit from being switched on inadvertantly.
Pos: 95 /Alle Produkte/Dummy_module/Abstand 3pt @ 11\mod_1251901846864_0.doc @ 72826 @
Pos: 96 /Pumpen/Schlammsauger/MIDI Floating Fountain LM/Montage Düse MIDI Floating Fountain @ 10\mod_1248703433937_121.doc @ 65830 @
Nozzle assembly (B)
Place nozzle (2) on the pump unit (1), turn in and tighten manually.
Nozzle change (B, D)
Note: When the float body is already fitted, it need not be removed when changing the nozzles.
MIDI Floating Fountain LM 2.2 kW and 4 kW:
Unscrew the nozzle (2), remove and fit different nozzle. If the nozzle is too tight to remove by hand, use an oil filter key (3).
MIDI Floating Fountain LM 1.1 kW:
Unscrew the nozzle (2), remove and fit different nozzle. If the nozzle is too tight to remove by hand, use an oil filter key (3).
Attention: The 1.1 kW pump unit is equipped with a reduction piece (4)! Should the reduction piece also become loose
when unscrewing the nozzle (2), screw the reduction piece back into the pump unit.
Pos: 97 /Pumpen/Schlammsauger/MIDI Floating Fountain LM/Montage Schwimmer MIDI Floating Fountain @ 10\mod_1248703849002_121.doc @ 65917 @
Float body installation (C,D)
Place the float body (5) on the pump unit (1), turn the float body (5) clockwise against the stop until the four fastening
flanges (6) are visible. Tighten the float body (5) using screws (7), washers (8) and nuts (9) to the fastening flanges (6).
Pos: 98 /Pumpen/Schlammsauger/MIDI Floating Fountain LM/Montage Beleuchtuns-Set Lunaqua 10 @ 10\mod_1248704110228_121.doc @ 65944 @
Fitting the spotlight set Lunaqua 10 (optional) (E-L)
Three Lunaqua 10 spotlight sets can be fitted to the unit. The spotlight sets are available as accessories. Ask your
OASE specialist dealer.
Transformer installation (E,F): Ensure that the float body is NOT fitted. Tighten the transformer (10) using screws (12),
washers (13) and nuts (14) to the transformer mounting plate (11). Tighten the transformer mounting plate (11) using
screws (15), washers (16) and nuts (17) to the pump unit (1).
Fit the float body (G,H): Place the float body (5) on the pump unit (1), turn the float body (5) clockwise against the stop
until the four fastening flanges (6) are visible. Tighten the float body (5) using screws (7), washers (8) and nuts (9) to
the fastening flanges (6).
Installation of the Lunaqua 10 lamps (I-L): Connect the plug of the connection cable (20) to the Lunaqua 10 (18), turn in
and firmly tighten the screws (21). Screw the spotlight holder (19) to the Lunaqua 10 (18) using the clamping
screws (22) and square nuts (23). Tighten the spotlight holder (19) to the float body (5) using screws (24) and washers
(25).
Connect three Lunaqua 10 each to one transformer. For this purpose, remove the screws (21) and the cover cap (26)
on the transformer. Connect the plug of the connection cable (20) to the transformer, turn in and firmly tighten the
screws (21).
Avoid kinking the connection cables (L). If necessary, bundle connection cables with cable binders.