SECTION 13: Specifications, continued
Dimensions
Footswitch
Remote Communication
Operating Environment
Transport and Storage Conditions
Symbology
AC POWER
TYPE B APPLIED PART EQUIPMENT
PROTECTIVE EARTH (GROUND)
Footswitch not for operating theatres
IPX1
Protection Class- IPX1
IPX1 Classification of ingress of water
Caution: Refer to accompanying documents
O/ I
AC Power Switch (0 = Off, | = On)
SECTION 14: Classifications
• Type of protection against electric shock:
• Degree of protection against electric shock:
• Degree of protection against the harmful ingress of water:
• Mode of operation:
• Degree of safety of application in the presence of a flammable
anaesthetic mixture with air or with oxygen or nitrous oxide:
• According to medical device directive:
SECTION 15: disposal of unit
U.S. - Dispose of the system components in accordance with state and local laws.
EU - Dispose of in accordance with the Waste Electrical and Electronic Equipment Directive 2002/96/EC of the
European Parliament and the Council of the European Union.
Height: 6 in (15,24 cm)
Width: 9.5 in (24,13 cm)
Depth: 8 in (20,32 cm)
Handpiece Cable length: 6.5 ft. (2.0 M)
Auxillary Footswitch Cable length: 8ft. (2.4 M)
Water Supply Line length: 8 ft. (2.4 M)
Air Supply Line length: 10 ft. (3.04 M)
Protection Class IPX1. Not for operating theatres.
Frequency:
2405 to 2480 MHz
Power:
< 1mW
Channels:
16
Temperature: 15 to 40 Deg. Celsius (59 to 104 Deg. Fahrenheit)
Relative Humidity: 30% to 75% (non-condensing)
Temperature: -40 to 70 Deg. Celsius (-40 to 158 Deg. Fahrenheit)
Relative Humidity: 10% to 100% (non-condensing)
Atmospheric Pressure: 500 to 1060 hPa
Class 1
Type B
Ordinary
Continuous
Equipment not suitable for use in the presence of
flammable anaesthetic or oxygen.
IIA (rule 9)
20
MEDICAL EQUIPMENT
WITH RESPECT TO ELECTRIC SHOCK, FIRE AND
MECHANICAL HAZARDS ONLY IN ACCORDANCE WITH UL-
2601-1/60601-1, CAN/CSA C22.2 NO.601.1
13VA
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1) this device may not cause harmful interference, and
2) this device must accept any interference received,
including interference that may cause undesired operation.
FCC ID:TF3-DPD81675
IC: 4681B81675
Dispose of in accordance with the Waste Electrical and
Electronic Equipment Directive 2002/96/EC of the
European Parliament and the Council of the European
Union