Technical Specifications; Preliminary Checks; Installation Dimensions - APRITECH XR 24 Guía Para El Instalador

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31
Page 6
XR 24
Guide for the installer
Thank you for choosing our product. The MANUFACTURER is sure you
will get the performances you expect to satisfy your requirements.
All our products are the result of a many years' experience in the
field of the automated systems, strengthened by being part of a
world leading group in this sector.
In the middle of the manual you will find a detachable
booklet containing all the images for the installation.
The XR 24 automated system consists of a non-reversing electro-
mechanical operator, designed for automating the opening of
gates with one or two leaves, with maximum length of 2.5m.
A handy, safe releases system, with personalised key, moves the
leaf in case of a power cut or fault.
The two articulated arms are designed for moving gates with very
large pilasters. The distance between the hinge and the gear-
motor securing point can be up to 220 mm. Thanks to the special
geometry of the two arms, all possible shearing points have been
eliminated.
IMPORTANT WARNINGS FOR THE INSTALLER
• Carefully read the whole manual before beginning to install the
operator.
• Store the manual for future reference.
• Correct operation and the declared technical characteristics can
be obtained only by respecting the indications in this manual and
using MANUFACTURER accessories and safety devices.
• To guarantee an adequate level of safety of the automated
system, the use of a control unit with an adjustable electronic
clutch is necessary due to the lack of a mechanical clutch .
• The automated system was designed and built to control vehicle
access. Avoid any other use.
• The operator cannot be used to move safety exits or gates
installed on emergency routes (escape routes).
• Do not transit when the gate is moving.
• Anything not expressly specified in this manual is not permitted.
1. COMPONENTS (Fig. 1)
Pos.
Gearmotor
a
Transformer
b
Control unit (if on board)
c
Release device
d
Receiver module (optional)
e
Mechanical stops
f
Transmission arm
g
Covering housing
h
Rear bracket
i
Lower housing
j
Description

2. TECHNICAL SPECIFICATIONS

Electric motor power supply
Absorbed power
Max torque
Nominal torque
Max angular speed
Max leaf
a b
Max leaf weight.
b
Use frequency at 20°C
Consecutive cycles at 20°C
Mximum continuous operating time
Protection Class
Operating ambient temperature
Noise level
Operator weight
Dimensions
For leaves with a length L>2m, an electric lock must be installed
a
to guarantee locking the leaf.
The weight P of the leaf is a function of the length L. Check if your
b
leaf is in the zone shown in the graph of fig. 2.
3. ELECTRICAL CONNECTIONS (Fig. 4)
Pos.
Description
Gearmotor with built-in Con-
a
trol unit
Gearmotor without Control
b
unit
a
Flashing lamp
c
Key-operated selector switch
d
Photocell transmitter
e
Photocell receiver
f
Electric lock
g
b
Only for two leaf applications.
a
Obligatory for leaf L>2m.
b
The lay-out refers to an installation with two motors, with
all safety and signalling devices connected.
For two-motor applications, use a cable, type H05RN-F to
connect the MASTER and SLAVE operators.
4. INSTALLATION

4.1. PRELIMINARY CHECKS

To ensure a correctly operating automated system, the structure
of the gate to be moved must satisfy the following requirements:
• The mechanical construction elements must comply with the
provisions of the EN12604 and EN 12605 standards.
• leaf length must conform to the operator characteristics (see
paragraph 2)
• sturdy, rigid gate structure, suitable for the automated system
• smooth, uniform gate movement, without any friction and jam-
ming during the entire opening;
• adequately sturdy hinges, in good condition
• an efficient earth socket for connection of the operator
We advise you to carry out the metalwork jobs if any, before
installing the automated system.
The condition of the gate structure directly influences the re-
liability and safety of the automated system.
If the leaf to be motorised incorporates a door for the pedestrian
passage it is compulsory to add a safety switch on the door,
connected to the stop input, in order to inhibit the operation
of the automated system when the door is open.
The gearmotor cannot be used to move safety exits or gates
fitted on emergency routes (escape routes).

4.2 INSTALLATION DIMENSIONS

Procedure for finding the securing position of the operator, using
Fig. 5 to help you:
24 V
40 W
250 N/m
165 N/m
13 °/sec
2.5 m
See graph
fig. 2
80 cycles/day
30
O.T. 17 min.
IP44
-20°C
+55°C
<70 dB (A)
7 Kg
See fig. 3
Cables section
3x2.5 mm
2
2x2.5 mm
2
2x1.5 mm
2
2x0.5 mm
2
2x0.5 mm
(BUS)
2
2x0.5 mm
(BUS)
2
2x1 mm
2

Publicidad

Tabla de contenido
loading

Tabla de contenido