3.5 Configuration of the controller
Fully programmable charge algorithm (see the software page on
our website) and eight preprogrammed charge algorithms,
selectable with a rotary switch:
Pos
Suggested battery
Gel Victron long life (OPzV)
0
Gel exide A600 (OPzV)
Gel MK
Gel Victron deep discharge
Gel Exide A200
AGM Victron deep discharge
1
Stationary tubular plate
(OPzS)
Rolls Marine (flooded)
Rolls Solar (flooded)
Default setting
Gel Victron deep discharge
Gel Exide A200
2
AGM Victron deep discharge
Stationary tubular plate
(OPzS)
Rolls Marine (flooded)
Rolls Solar (flooded)
AGM spiral cell
3
Stationary tubular plate
(OPzS)
Rolls AGM
PzS tubular plate traction
4
batteries or
OPzS batteries
PzS tubular plate traction
5
batteries or
OPzS batteries
PzS tubular plate traction
6
batteries or
OPzS batteries
Lithium Iron Phosphate
7
(LiFePo
) batteries
4
Note 1: divide all values by two in case of a 12V system and multiply by two
in case of a 48V system.
Note 2: equalize normally off, see sect. 3.8 to activate.
Note 3: any setting change performed with Bluetooth or via VE.Direct will
override the rotary switch setting. Turning the rotary switch will override prior
settings made with Bluetooth or VE.Direct.
Type
Absorption
Float
V
V
28,2
27,6
28,6
27,6
28,8
27,6
29,4
27,6
29,8
27,6
30,2
27,6
30,6
27,6
28,4
27,0
Equalize
dV/dT
V
mV/°C
@%I
nom
31,8
-32
@8%
32,2
-32
@8%
32,4
-32
@8%
33,0
-32
@8%
33,4
-32
@25%
33,8
-32
@25%
34,2
-32
@25%
n.a.
0