5. Commissioning, operation
Parity
Parity
Register value
None
0 (standard)
1
Even
Tag number
Here, a transmitter name with up to 16 characters can be entered.
5.4.2.7 Status register
Register Function
00200
Error memory
00201
Error memory reset
00202
Software reset
00203
Resetting to standard
After a restart (voltage supply was interrupted), the error memory is reset. Writing 0x0001 in
register address 00201 has the same effect.
Description of the error memory
Bit
Description
1
Pressure signal above the upper limit value (in bar abs., →see data sheet SP 60.77)
3
Temperature signal below the lower limit value (< -40 °C [-40 °F])
4
Temperature signal above the upper limit value (> 80 °C [176 °F])
5
Communication error pressure/ temperature sensor
6
Liquefaction of the SF
7
Gas density above the upper limit value (based on the full scale of the density measuring
range in bar abs. at 20 °C [68 °F])
10
Recurring Modbus
Example: 0x0082
Bit 1 and 7 are set. The upper limit values for pressure and gas density are exceeded.
Software reset
Writing 0x0001 in register 202 causes a software reset. After this process all changed
parameters take effect (e.g. change of address).
WIKA operating instructions gas density sensor, model GD-20
Value definition, triggering the
function
16 bit (see the following table)
Writing 0x0001
Writing 0x0001
Writing 0x0001
gas
6
communication error
®
EN
Writable
Read only
Yes
Yes
Yes
23