- Keep the arm in position and wait for the
acoustic confirmation signal.
- Return the measuring arm to the rest posi-
tion.
If the measuring arm is returned to the rest
position after acquiring the data relating to
only one plane or if first the outer plane data
then the inner plate data are acquired, the "A
23" message is displayed and the acquired
data are not considered.
- Perform a spin
in the version with manual sensor, proceed
as follows:
- Press the
chine for entering distance d1 relative to
the internal side (the distance LED lights
up on the panel).
- Bring the end of the measuring arm level
with the plane selected for applying the
internal weight (Fig. 13 for ALU 1P, Fig. 10
for ALU 2P). In Alu 1 P, the centre of the
peg at the end section of the arm is used
as the reference for the centre line of the
weight (fig.13). In Alu 2 P, the rim edge is
taken as a reference, since the inner weight
is of the conventional clip type.
54
14
key to prepare the ma-
Pay maximum attention when the end
of the arm is being placed in an area of
the rim free of discontinuity, so that the
weight can be applied in that position.
- Read the internal distance d1 from the
body on the rule.
- Modify the value on the right display by
pressing the
the previously measured distance d1.
- Press the
the machine for entry of the d2 distance
relating to the outer side (the distance LED
lights up on the panel).
- Position the end of the measuring arm on
the plane chosen for the application of the
outer weight, as previously described for
the inner side.
- Read the distance d2 from the body on
the rule.
- Modify the value on the right display by
pressing the
the previously measured distance d2.
- Press the
machine for entering the nominal wheel
diameter.
- Read the rated rim diameter value on the
tyre.
- Modify the value displayed on the right
display by pressing the
keys to get the previously measured nomi-
nal diameter.